Note:
The signal converter can be programmed with or without mechanical process connector assembled.
• Connect the device to the power supply
(see the section "Electrical installation/
connection".
• Press
3 times.
AKS 4100
QUICK SETUP?
YES
NO
• Press
AKS 4100
PROBETYPE
SINGLECABLE
• Press
or
to select between SINGLE,
COAXIAL D14 and COAXIAL D22.
Choose SINGLE and press
AKS 4100
PROBE LENGTH
05000 mm
• Press
to change the PROBE LENGTH.
Press
to change the position of the
cursor.
Press
to decrease the value or
increase the value.
Press
to confirm.
AKS 4100
SCALE 4mA
04946 mm
Default screen
AKS 4100
DISTANCE
5000 mm
• Press
AKS 4100
1.0.0
QUICK SETUP
• Press
AKS 4100
2.0.0
SUPERVISOR
• Press
AKS 4100
2.0.0
___________
Enter password:
AKS 4100
2.1.0
INFORMATION
© Danfoss | DCS (MWA) | 2017.07
Quick Setup (all values below are only examples)
• Press
to change of SCALE 4 mA.
Press
to change the cursor position.
Press
to decrease the value or
increase the value.
Press
to confirm.
AKS 4100
SCALE 20mA
• Press
to change of SCALE 20 mA.
Press
to change the cursor position.
Press
to decrease the value or
increase the value.
Press
to confirm.
to confirm.
AKS 4100
QUICK SETUP
COMPLETED IN 8
• Wait for QUICK SETUP to complete
8-second timeout
AKS 4100
to
QUICK SETUP
How to force mA output (all values below are only examples)
• Press
AKS 4100
• Press
AKS 4100
SET OUTPUT
• Press
AKS 4100
SET OUTPUT
• Press
to decrease the value or
increase the value.
Press
to confirm.
AKS 4100
SET OUTPUT
to
00070 mm
to
1.0.0
2.2.0
TESTS
2.2.1
3.5 mA
to
8 mA
• Press
to confirm.
AKS 4100
1.0.0
STORE NO
• Press
or
to select either
STORE NO or STORE YES.
Press
to confirm.
Default screen appears:
AKS 4100
DISTANCE
5000 mm
Quick Setup completed
You have the possibility of checking
your settings by pressing
AKS 4100
SINGLE CABLE
5000 mm
(0%) 4 mA
4877 mm
(100%) 20 mA
120 mm
Press
to return to
default screen.
• Press
4 times to return to default
screen.
Default screen appears:
AKS 4100
DISTANCE
5000 mm
Force mA completed and disabled
DKRCI.PI.SC0.F3.ML | 520H8392 | 8
twice.
Need help?
Do you have a question about the AKS 4100U and is the answer not in the manual?
Questions and answers