Overfl Ow Pipe - GE GTUP270EMWW Technical Service Manual

24- and 27-in. unitized laundry centers
Hide thumbs Also See for GTUP270EMWW:
Table of Contents

Advertisement

Pressure Dome Cleanout Port
The pressure dome cleanout port is located near the
left front area of the outer tub. The hose connected
to the pressure switch is attached to the top of the
pressure dome. (See
Component Locator Views
To access the pressure dome cleanout port:
1. Remove the front panel. (See
2. Using a small fl at blade screwdriver, pry down
and remove the 2 spring steel clamps from the
bottom of the pressure dome.
3. Pull down and remove the dome cap and O-ring.
O-ring
4. Clean the interior of the dome, O-ring, and cap
before reassembly.
5. Check for leaks after installing the O-ring and
cap.
.)
.)
Front Panel
Pressure Dome
Cap
– 43 –
Overfl ow Pipe
The overfl ow hose is clamped on the right front of
the tub and incorporates a high loop to minimize
suds leak. The overfl ow hose is attached to the
outer tub with 3 wire ties and a 5/16-in. hex-head
clamp.
Wire Tie
Clamp
Wire Tie
Wire Tie