Dryer Components - GE GTUP270EMWW Technical Service Manual

24- and 27-in. unitized laundry centers
Hide thumbs Also See for GTUP270EMWW:
Table of Contents

Advertisement

WARNING: Sharp edges may be exposed when
servicing the laundry center. Use caution to avoid
injury. Wear Kevlar gloves or equivalent protection.
Note: Combined Phillips-head/square-drive recess
screws are utilized throughout this appliance. Either
Phillips or square-drive screwdrivers can be used to
extract or install these screws.
Shipping Rod
There is a new location for the shipping rod. The rod
is inserted and removed through a hole located on
the lower right side of the cabinet and now passes
behind the transmission.
The shipping rod passes through the chassis rod
brackets and the platform brackets.
Chassis Rod
Bracket
Platform Brackets
Leveling Legs
The front legs are screw type and are adjusted
by turning the legs counterclockwise to increase
height. The rear leveling legs are contained in an
assembly and will level the rear of the washer left to
right.
To level the washer, tilt the washer forward to lift the
rear legs off the fl oor, then gently set it back down.
Adjust the front leveling legs to level the washer
front to back and left to right across the front. Using
a 9/16-in. open-end wrench, tighten the lock nut on
each front leg fi rmly against the base.

Dryer Components

Shipping Rod
Chassis Rod
Bracket
Rod Inlet Hole
– 21 –
Service Panel
It is necessary to remove the service panel to
access the mini-manual, water pressure sensor,
washer control board, and fuses. The service panel
is attached to the cabinet with 2 Phillips-head
screws.
To remove the service panel:
1. Remove 1 screw from the top left and top right
corners of the service panel.
2. Lift the service panel and pull it forward to
release the panel from the cabinet.

Hide quick links: