BVS 10 ATEX E II 1G Ex ia IIC User Manual Betriebsanleitung Stratos Pro A2... pH Portavo® 904(X) PH Stratos®Pro English deutsch A2... PH Betriebsanleitung x ia IIC T3/T4/T6 ATEX E 089 X Aktuelle Produktinformation: Aktuelle Produktinformation: www.knick.de Latest Product Information: www.knick.de www.knick.de...
Page 3
Basics Return of products under warranty Please contact our Service Team before returning a defective device. Ship the cleaned device to the address you have been given. If the device has been in contact with process fluids, it must be decontaminated/ disinfected before shipment.
Package Contents Check the shipment for transport damage and completeness. The package of the Portavo 904(X) PH includes: • The Portavo 904(X) PH incl. 4 AA batteries and premounted quiver • Carrying strap • Quickstart instructions in various languages • Specific test report •...
In official EU languages and others. • EC Declarations of Conformity Certificates • IECEx • ATEX Quickstart Guides Installation and first steps: • Operation • Menu structure • Calibration • Error messages and recommended actions Various languages on CD-ROM and on our website: www.knick.de...
Overview of the Portavo 904(X) PH The Portavo 904(X) PH is a portable pH meter. A plain-text line on the high- contrast LCD screen makes operation vir- tually self-explanatory. The device variant 904 X PH is available for applications in hazardous locations up to Zone 0. The meter stands out by the following features: •...
Overview of the Portavo 904(X) PH Value-Added Features Memosens The Portavo 904 can communicate with Memosens sensors. When these digital sensors are connected to the meter, they are automatically identified and indicated by the logo shown on the right. Furthermore, Memosens allows the storage of calibration data, which will be available and can still be used when the sensor is connected to another Memosens-capable device.
Overview of the Portavo 904(X) PH Protective Cover The front of the meter is protected by a cover, which can be completely flipped over and secured to the back for oper- ation. A label on the inner side of the cover explains the control functions and device messages.
Overview of the Portavo 904(X) PH Display The meter has a three-line display for representing alphanumeric informa- tion such as measurement and calibra- tion data, temperatures and date/time. Additional information is provided by means of icons (Sensoface, battery icon, etc.). Some typical displays are shown here.
Overview of the Portavo 904(X) PH Keypad The keys of the membrane keypad have a noticeable pressure point. They have the following functions: on/off Switches the meter on and displays the device and calibration data (see Start-Up) meas Switches the meter on / Activates measuring mode / Stops the data logger Starts calibration...
Start-Up Check the shipment for transport damage and completeness (see Package Contents). NOTICE! Do not operate the device when one of the following conditions applies: • the device shows visible damage • the device fails to perform the intended function •...
Start-Up A battery icon in the display indicates the battery power level: Icon fully filled Batteries at full capacity Icon partially filled Battery capacity is sufficient Icon empty Battery capacity not sufficient; calibration is possible, no logging Icon blinks Max. 10 operating hours remaining, measurement is still possible NOTICE! It is absolutely necessary to replace the batteries.
Start-Up Connecting a Sensor The Portavo 904(X) PH provides several connections so that many types of sensors can be used for measurement. Note that only one sensor may be connected to the meter at a time. The meter automatically recognizes a connected Memosens sensor and switches accordingly.
Start-Up Switching On the Meter When you have connected the sensor, you can switch the meter on by pressing the on/off or meas key. When the meter is switched on with the on/off key, first a self test is performed and then the calibration data and settings are displayed before the meter switches to measuring mode.
Calibrating CALIMATIC Calibration (Calibration with automatic buffer recognition) The calibration method is selected in the configuration menu. Calibration is required to adjust the sensor to the meter. It is indis‑ pensable for achieving comparable and reproducible measurement results. Measurement Calibration method, the number of calibration points and the buffer set have been selected in the configuration menu.
Page 19
Calibrating DATA INPUT Calibration (Calibration by entering known sensor values) The calibration method is selected in the configuration menu. Measurement to select the value for the zero point. to select the value for the slope. The calibration data will be displayed successively: Date and time ZERO POINT SLOPE...
Calibrating MANUAL Calibration The calibration method is selected in the configuration menu. Measurement The number of calibration points has been selected in the configuration menu. pH display blinks Take the temperature‑corrected pH value from the buffer description and enter it using mV display blinks Depending on the number of calibration points, the procedure described above for CAL 1/2/3 is...
Page 21
Calibrating CAL SOP Calibration (Option, must have been configured in Paraly SW 112 software) Option 001 SOP (Standard Operating Procedure) meets specific requirements of the pharmaceutical and biotechnological industries. In the Paraly SW 112 software, you specify which buffers are to be used in which sequence.
Page 22
Calibrating ORP OFFSET Calibration – available with pH/ORP combo sensor connected – Selected in the configuration menu. Measurement You can specify an offset for the ORP value measured by the sensor. ORP OFFSET After calibration has been activated, the following values are listed in the display: •...
Page 23
Calibrating TEMP. OFFSET Calibration (Option) Temperature calibration (offset) Selected in the configuration menu. Measurement You can specify an offset for the tem‑ perature measured by the sensor. TEMP. OFFSET After calibration has been activated, the following values are listed in the display: •...
Page 24
Calibrating FREE CAL Calibration (Free selection of calibration method) FREE CAL calibration is selected in the configuration menu. Measurement to select the required calibration CALIMATIC blinks method (CALIMATIC, DATA INPUT, CAL SOP (Option), ORP OFFSET (with pH/ORP combo sensor connected), TEMP. OFFSET (Option) or MANUAL).
Measuring Keys for Once you have completed all preparations, you can start with measurement the actual measurement. 1) Connect the desired sensor to the meter. Some sensors require a special preparation. Please proceed according to the operating instructions for the sensor. 2) Switch the meter on using the on/off or meas key.
Data Logger The Data Logger The meter provides a data logger. Prior to use, it must be configured and then activated. You can choose from the following logger types: • DIFF (signal-controlled logging of measured variable and temperature) • INT (time-controlled logging at a fixed interval) •...
Data Logger Operating Modes of the Data Logger (Logger Type) Manual logging when logger is activated (SHOT) In this mode, a measured value is recorded when the STO key is pressed. Measurement Logger activated The measured value is saved to the address of the last recorded value + 1 Manual logging when logger is deactivated Measurement Logger deactivated...
Page 28
Data Logger Difference (DIFF) When the delta range (process variable and/or temperature) related to the last entry is exceeded, a new entry is created and the delta range is displaced upwards or downwards by the delta value. The first entry is automatically created when the data logger is started.
Data Logger Data Logger Menu Select using arrow keys, confirm by pressing set. Logger display CONT Select start address and start the data logger START Deletes all entries and starts the data logger at start address 0001 Deletes all entries Select logger type and configure: DIFF, INT, DIFF+INT, SHOT (see table below) Overview of data logger menu (default in bold print)
Data Logger Configuring the Data Logger Prerequisite: The data logger is stopped (press meas). Measurement Measured value is maintained Logger: CONT blinks Logger: START blinks Logger: DEL blinks Logger: SET blinks Logger: Current logger type Select desired logger type using st: blinks DIFF, INT, DIFF+INT or SHOT.
Data Logger Starting the Data Logger using CONT Prerequisite: Data logger is configured. Every time the meter has been switched off, the data logger must be restarted (exception: SHOT). Measurement Measured value is maintained Logger: CONT blinks Address of the last recorded value If desired: Select start address using st.
Data Logger Displaying the Logger Data Pressing the RCL key displays all stored values. The Paraly SW 112 software allows convenient management of the data logger. Measurement The “RCL” icon and the last Use st to select the desired address. Empty recorded value is displayed.
Data Logger Stopping the Data Logger You can stop the data logger at any time by pressing the meas key. Measurement, logger activated Data logger is stopped. “LOGGER” and “active logger type” icons are no longer displayed. It is still possible to hold a measured value by pressing STO and send it to any desired address.
Clock Press the clock key to access the clock mode. Date and time will be displayed in the format as set in the configuration menu. To set the clock, proceed as follows: Display of time+date Hour display blinks Set value. SET HOUR Minute display blinks Set value.
Options Option 001 SOP Option 001 SOP (Standard Operating Procedure) meets specific requirements of the pharmaceutical and biotechnological industries. It comprises: 1. SOP Cal In the Paraly SW 112 software, you specify which buffers are to be used in which sequence.
Options Option 002 Temperature Calibration Selecting the temperature calibration (TEMP. OFFSET) In measuring mode, press the set key. 1) Select CAL (calibration) and confirm by pressing set. 2) Select the TEMP. OFFSET calibration mode and confirm by pressing set. Performing the temperature calibration (TEMP. OFFSET) In measuring mode, press the cal key.
Options Enabling Options / TAN Input When you have bought an option, you receive a document with a code (TAN) for enabling this option on your device. Press the set key to access the configuration mode. Use the arrow keys to select the “TAN TEMP CAL” function, for example, where you can enter the TAN for enabling the option.
Options Passcodes for CONF and CAL With Option 001 SOP only: Press the set key to access the configuration mode. Use the arrow keys to select “Setup Code” for setting a passcode for configuration and / or “Cal. Code” for setting a passcode for calibration. NOTICE! If you lose your passcode, you will have no access to the configuration menu.
Paraly SW 112 Software The Paraly SW 112 software supplements the Portavo series. It allows convenient management of the data that have been acquired by the meters as well as simple and clear configuration of the meters. Paraly SW 112 starts automatically when the Portavo USB port is connected to the computer.
Error Codes and Device Messages Error messages are indicated as “ERROR …” on the display. Information on the sensor condition is indicated by the “Sensoface” icon (friendly, neutral, sad) possibly accom- panied by an info message (“INFO …”). Example of an error message: Example of a “Sensoface”...
Error Codes and Device Messages “Sensoface” Messages The “Sensoface” icon provides information on the sensor condition: Sensoface Meaning Sensor is okay Calibrate the sensor soon Calibrate or replace the sensor The “neutral” and “sad” Sensoface icons are accompanied by an “INFO …” message to give a hint to the cause of deterioration.
Error Codes and Device Messages Error Messages The following error messages can be shown in the display. Message Cause Remedy Battery empty Replace batteries blinks ERROR 1 pH value out of range Check whether the measurement ERROR 2 ORP value out of range conditions correspond to the adjusted measuring range.
Robust field case (for meter, sensor, ZU 0934 various small parts and user manual) Replacement quiver (5 units) ZU 0929 Memosens lab cable, M8, 4 pins CA/MS-001XFA-L Li-ion battery ZU 0925 Please visit our website for more information on our product range: www.knick.de...
Product Line pH Sensors Please visit our website for more information on our product range: www.knick.de Temperature detectors Note: When a Memosens sensor is connected, the temperature detector of the Memosens sensor is used. When no Memosens sensor is connected, the Portavo 904(X) PH can be used as a temperature meter.
Specifications pH/mV input pH socket, DIN 19 262 (13/4 mm) pH range -2 … 16 Decimal places * 2 or 3 Input resistance 1 x 10 Ω (0 … 35 °C) Input current 1 x 10 (at RT, doubles every 10 K) Measuring cycle Approx.
Page 47
MANUAL Manual calibration with entry of individual buffer values DATA INPUT Data entry of zero and slope Calimatic buffer sets -01- Mettler-Toledo 2.00/4.01/7.00/9.21 -02- Knick CaliMat 2.00/4.00/7.00/9.00/12.00 -03- Ciba (94) 2.06/4.00/7.00/10.00 -04- NIST technical 1.68/4.00/7.00/10.01/12.46 -05- NIST standard 1.679/4.006/6.865/9.180 -06- HACH 4.01/7.00/10.01/12.00...
Page 48
Specifications Connections 1 x pH socket, DIN 19 262 2 x 4-mm socket for separate temperature detector 1 x M8 socket, 4 pins, for Memosens lab cable 1 x Micro USB-B for data transmission to PC Portavo 904 X: Be sure to observe the safety instructions when using the USB port. Display LCD STN 7-segment display with 3 lines and icons Sensoface...
Page 49
Specifications RoHS conformity According to directive 2011/65/EC Power supply Portavo 904 Batteries: 4 x AA alkaline or 4 x NiMH (rechargeable) or 1 x Li-ion battery, USB chargeable Portavo 904 X 4 x AA batteries For battery types, see Control Drawing No. 209.009-110 Operating time Approx.
Page 54
Index on/off key 12 Operating modes of the data logger 27 Option 001 SOP 35 Option 002 TEMP. OFFSET 36 Options, overview 35 Options, TAN input 37 Order numbers (accessories) 43 ORP OFFSET calibration 22 Overview 8 Overview of configuration 17 Overview of error messages 42 Package contents 6 Panasonic Pro Power LR6 battery 14...
Page 55
Index Rating plate 10 RCL, displaying the logger data 32 RCL key 12 Real-time clock 8 Rechargeable battery, Li-ion 13 Recorded data, display 32 Redox calibration 22 Reference numbers (accessories) 43 Registered trademarks 3 Replacement quiver (accessory) 43 Replacing the batteries 14 Reset to factory settings (Default) 17 Return of products under warranty 3 Safety instructions 7...
Page 56
Index SOP calibration 21 SOP, Option (Standard Operating Procedure) 35 Specifications 46 Specific test report 7 Start address (data logger) 27 Starting the data logger using CONT 31 Starting the data logger using START 31 START, starting the data logger 31 Start-up 13 STO key 12 STO, manual logging 27...
Page 57
Index USB port 15 USB port (battery) 13 USB port, micro 8 Value-added features 9 Viewing logger data 32 Viewing recorded data 32...