Checking Resistance - Viking VUWC244DRSS Service Manual

Table of Contents

Advertisement

Note the resistance reading and compare to the chart below. When determining what temperature range
to reference pick the closest given point and either add or subtract a small value so that it falls in line
with the flow of the chart.
EXAMPLE: A thermistor setting at a room temperature of 72˚F should have an approximate resistance
value of 2.2K.
˚C
˚F
K-Ohms
0
32
5.630
0.6
33
5.492
1.1
34
5.359
1.7
35
5.229
2.2
36
5.102
2.8
37
4.979
3.3
38
4.860
3.9
39
4.743
4.4
40
4.630
5.0
41
4.520
5.6
42
4.413
6.1
43
4.309
6.7
44
4.207
7.2
45
4.108
7.8
46
4.012
8.3
47
3.919
8.9
48
3.828
9.4
49
3.739
10.0 50
3.653
10.5 51
3.569
11.1 52
3.487
11.7 53
3.407
12.2 54
3.330
12.8 55
3.254
13.3 56
3.180
13.9 57
3.109
14.4 58
3.039
15.0 59
2.971
15.5 60
2.904
16.1 61
2.840
16.7 62
2.776
17.2 63
2.715
2010 - Viking Preferred Service
˚C
˚F
K-Ohms
17.8
64
2.655
18.3
65
2.597
18.9
66
2.540
19.4
67
2.484
20.0
68
2.430
20.5
69
2.378
21.1
70
2.326
21.6
71
2.276
22.2
72
2.227
22.8
73
2.179
23.3
74
2.133
23.9
75
2.088
24.4
76
2.043
25.0
77
2.000
25.5
78
1.958
26.1
79
1.917
26.6
80
1.877
27.2
81
1.837
27.8
82
1.799
28.3
83
1.762
28.9
84
1.725
29.4
85
1.690
30.0
86
1.655
30.5
87
1.621
31.1
88
1.588
31.6
89
1.556
32.2
90
1.524
32.7
91
1.493
33.3
92
1.463
33.9
93
1.434
34.4
94
1.405
35.0
95
1.377
43
SMR-0005