The latest software is version 1.9. This software version will incorporate an additional 30 minutes of
compressor "off time" when 5 hours of accumulated run time has been obtained. The defrost period will
initiate at the beginning of the next call for cooling. At this point the compressor remains off until the
conclusion of the 30 minute defrost period.
2.4
Software Versions
To determine the software version of the dual zone, enter into the diagnostics mode on the User Interface
board.
This is accomplished by pressing and holding the "Warmer" keypad while pressing the "Colder" keypad
four (4) times within five (5) seconds. The display will flash both the software and firmware version.
To exit the diagnostics mode repeat the above process or let the User Interface time out of the mode after
five (5) minutes of no keypad functions.
Firm Ware
Soft Ware
1.0
1.5
1.0
1.7
1.0
1.8
1.0
1.9
NOTE: All part orders will receive software version 1.9
2010 - Viking Preferred Service
Compressor off time Accumulated run time
20 Minutes
20 Minutes
25 Minutes
30 Minutes
10
12 Hours
5 Hours
5 Hours
5 Hours
SMR-0005