Damper
The fresh food compartment receives chilled air
via an electronic damper that is positioned at the
top rear of the fresh food compartment. The
damper is controlled by the main control board and
when open, allows the evaporator fan to push
chilled air from the evaporator into the fresh food
compartment.
To Remove the Damper
1. Remove the light cover.
2. Remove 4 Phillips screws and the light
assembly.
Evaporator
Evap.
Fan
Back
Freezer Side
Airflow
3. Remove the Styrofoam section covering the
4. Disconnect the damper wiring connector.
5. Carefully pull the damper out of the mullion and
Top
Duct
Entrance
Front
Duct
Exit
Bottom
– 15 –
damper.
Damper
remove.
Return
Front
Fresh Food Side
Damper
Air
Tower
Back