Last Fault; Priming Speed And Duration; Estar Speed; Pump Freeze Protect Operation - Jandy ePump Installation Manual

Variable speed pump user interface
Table of Contents

Advertisement

Page 12
4.4

Last Fault

This feature shows on the top display line, the most recent
unique fault message and on the bottom display line, the
second-to-last unique fault message. If there is no entry
for a fault, the display will show "*----------------*" on the
corresponding line. To select last fault, from the service setup
menu select LAST FAULT. Press MENU.
NOTE
The fault messages are stored in non-volatile
memory, and remain even with no power. To clear the
fault history, press either arrow key.
SELECT SERVICE SETUP
2
4.5

Priming Speed and Duration

The ePump™ controller will command the ePump™ to
operate at the priming speed for the priming duration
specified (except during timer program overlaps or follow-on
commands where the pump is not stopped before changing
speeds). From the service setup menu, select PRIMING using
the arrow keys. Press MENU.
PRIMING DURATION
2
To set priming speed, select PRIMING SPEED using the
arrow keys. Press MENU. Using the arrow keys, set the
priming speed to the desired value. Press MENU to accept
and store.
PRIMING SPEED
2
LAST FAULT
4
ePUMP
3
MENU
MIN: 3
4
ePUMP
3
MENU
RPM: 3450
3
4
ePUMP
MENU
To set priming duration, select PRIMING DURATION using
the arrow keys. Press MENU. Using the arrow keys, set the
priming speed to the desired value in minutes from 1 to 5
minutes. Press MENU to accept and store.
PRIMING DURATION
2
4.6

eStar Speed

œ
The "
" speed is intended to be used as an energy-efficient
setting that can be easily called-up by activating the eStar
preset speed from the keypad or remote closure. After this
speed has been determined by the installer, the eStar preset
may be set as follows: From the service setup menu, select
SET ESTAR SPEED. Press MENU. Using the arrow keys,
set the speed to the desired value. Press MENU to accept and
store.
2
4.7

Pump Freeze Protect Operation

When enabled to do so, the ePump™ controller monitors the
temperature inside the pump and will activate the ePump™
at the eStar speed when the temperature approaches freezing.
The run duration of the pump freeze protect operation is
adjustable from 30 minutes to 8 hours, or may be disabled
completely.
MIN: 3
3
4
ePUMP
MENU
1:eSTAR
RPM:1250
3
4
ePUMP
MENU