Low Voltage On Main Bus 1; Low Voltage On Main Bus 2; Original Issue - Cirrus SR22 Pilot Operating Handbook

Aircraft serials 22-3915 & subsequent 3600 pound takeoff weight
Table of Contents

Advertisement

Section 3A
Abnormal Procedures
Electrical System

Low Voltage on Main Bus 1

M BUS 1 Caution
1. Perform
ALT 1 Caution (Failure)
Amplification
Main Bus 1 Voltage is low, indicates Alt 1 failure; will typically be
associated with low M1 voltage Alt 1 current indications, Battery 1
discharge and ALT 1 Caution message.

Low Voltage on Main Bus 2

M BUS 2 Caution
1. Perform
ALT 1 Caution (Failure)
Checklists.
Amplification
Main Bus 2 Voltage is low, indicative of dual Alt 1 and 2 failures; will
typically be associated with low M1 and M2 voltages, Alt 1 and Alt 2
current indications, Battery 1 discharge, ALT 1 & 2 and M BUS 1 & 2
Caution messages, and ESS BUS Warning message.
Battery 1 Current Sensor
BATT 1 Caution
1. Main Bus 1, 2 and Non-Essential Bus Loads...................REDUCE
2. Main Bus 1, 2 and Essential Bus Voltages..................... MONITOR
3. Land as soon as practical.
Amplification
Battery 1 discharge while Alt 1 is functioning normally, indicative of an
internal power distribution failure within the MCU.
3A-12
M BUS 1
Checklist.
M BUS 2
and
ALT 2 Caution (Failure)
BATT 1
Cirrus Design
SR22
P/N 13772-004