National Instruments 9235 Getting Started Manual

National Instruments 9235 Getting Started Manual

8 ai, +/-29.4 mv/v, 24 bit, 10 ks/s/ch simultaneous, 120 om quarter-bridge completion
Hide thumbs Also See for 9235:

Advertisement

Quick Links

GETTING STARTED GUIDE
NI 9235
8 AI, ±29.4 mV/V, 24 Bit, 10 kS/s/ch
Simultaneous, 120 Ω Quarter-Bridge Completion

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments 9235

  • Page 1 GETTING STARTED GUIDE NI 9235 8 AI, ±29.4 mV/V, 24 Bit, 10 kS/s/ch Simultaneous, 120 Ω Quarter-Bridge Completion...
  • Page 2: Safety Guidelines

    This document explains how to connect to the NI 9235. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation. The guidelines in this document are specific to Note the NI 9235. The other components in the system might not meet the same safety ratings.
  • Page 3: Safety Voltages

    Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. NI 9235 Getting Started Guide | © National Instruments | 3...
  • Page 4: Safety Guidelines For Hazardous Locations

    III, or IV. Safety Guidelines for Hazardous Locations The NI 9235 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
  • Page 5: Special Conditions For Hazardous Locations Use In Europe And Internationally

    Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9235 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
  • Page 6: Electromagnetic Compatibility Guidelines

    This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the 6 | ni.com | NI 9235 Getting Started Guide...
  • Page 7: Special Conditions For Marine Applications

    In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. NI 9235 Getting Started Guide | © National Instruments | 7...
  • Page 8: Preparing The Environment

    Preparing the Environment Ensure that the environment in which you are using the NI 9235 meets the following specifications. Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing...
  • Page 9 Figure 1. NI 9235 Pinout NI 9235 Getting Started Guide | © National Instruments | 9...
  • Page 10: Connecting A Quarter-Bridge Sensor

    Measures the bridge voltage Provides the quarter-bridge completion Connecting a Quarter-Bridge Sensor You can connect quarter-bridge sensors to the NI 9235. Figure 2. Connecting a Quarter-Bridge to One Channel NI 9235 10 | ni.com | NI 9235 Getting Started Guide...
  • Page 11: Connecting Wires To A Spring-Terminal Connector

    C Series module or a flathead screwdriver with a blade smaller than 2.3 mm x 1.0 mm (0.09 in. x 0.04 in.). NI 9235 Getting Started Guide | © National Instruments | 11...
  • Page 12 1. Insert the screwdriver into a spring clamp activation slot to open the corresponding connector terminal. 2. Press a wire into the open connector terminal. 3. Remove the screwdriver from the activation slot to clamp the wire into place. 12 | ni.com | NI 9235 Getting Started Guide...
  • Page 13: High-Vibration Application Connections

    High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you use the NI 9965 backshell kit to protect connections to the NI 9235. NI 9235 Getting Started Guide | © National Instruments | 13...
  • Page 14: Where To Go Next

    NI 9235 Datasheet NI 9235 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services & Resources ni.com/services ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software 14 | ni.com | NI 9235 Getting Started Guide...
  • Page 15: Worldwide Support And Services

    You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9235 Getting Started Guide | © National Instruments | 15...
  • Page 16 U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2008—2015 National Instruments. All rights reserved. 374645B-01 Oct15...