2.1.10.2 MSS to MPT-HC interconnection
The MPT-HC can be connected in 4 different ways:
Two cables (MPT Access unit to MPT-HC) - par. 2.1.10.2.1
One cable (MPT Access unit to MPT-HC) - par. 2.1.10.2.2
Two cables (Core-E unit to MPT-HC) - par. 2.1.10.2.3
One cable (Core-E unit to MPT-HC) - par. 2.1.10.2.4
2.1.10.2.1 Two cables (MPT Access unit to MPT-HC)
Two cables connect an MPT-HC Access unit in the MSS to its MPT-HC (Figure 18 and Figure 19):
One cable is a 50 ohm coaxial cable to send the power supply to the MPT-HC.
The second cable is an Ethernet cable (optical or electrical).
The max cable length for electrical Ethernet connection is 100 m.
The max cable length for optical Ethernet connection is 450 m.
The standard delivery is up to 300 m. The cable for up to 450 m is available on demand.
The Ethernet electrical cable is provided with connectors to be mounted on site with the specific RJ45 tool
(1AD160490001). The Ethernet optical cable is preassembled and available in different lengths.
User Manual
Product information and planning

Figure 18. MSS to MPT-HC interconnection

3DB18809AAAA Issue 1
9500 MPR Rel. 3.1