2.8.5.2 RSSI Monitoring Point
The RSSI is available on the maintenance LEMO connector and is used to manually point the antenna
on the field.
The higher the voltage the higher RSSI and better aligned the antenna is.

Table 29. RSSI Table

Units
BNC (Vdc)
RSL (dBm)
-10
2.8.5.3 Waveguide Flange Data

Table 30. Waveguide Flange Data

L6
Waveguide
GHz
Type
WR137 WR137 WR113 WR113
2.8.5.4 MPT-HC Coupler
The coupler is used in the 1+1 HSB or 1+1/2x(1+0) FD co-polar configurations.
The coupler can be equal type (3 dB/3 dB insertion loss) or unequal type (1 dB on the main path/10 dB
on the secondary path).
The couplers are connected between the MPT and the antenna.
User Manual
Product information and planning
Measurement (with MPT-HC)
5
4.71
4.12
-20
-30
U6
7
8
GHz
GHz
GHz
3.5
2.9
2.3
-40
-50
-60
11
13
15
GHz
GHz
GHz
WR75
WR62
WR62
3DB18809AAAA Issue 1
1.71
1.11
0.59
-70
-80
-90
18
23
26
GHz
GHz
GHz
WR42
WR42
WR42
9500 MPR Rel. 3.1
0.14
-100
38
GHz
WR28