Advertisement

Quick Links

®
iMarc
9550 DS3 Probe
Installation Instructions
Document Number 9550-A2-GN10-00
September 2005
Contents
.................................................................................................. 17
................................................................................................... 17
................................................................................................. 17
.....................................................................
........................................................................................
.....................................................................................
....................................................................... 10
......................................................................... 11
........................................................................ 12
............................................................................................. 14
....................................................................... 16
........................................................................ 18
.................................................
....................................................
.....................................................
....................................................................
...................................................................
................................................. 13
1
...................................... 19
2
3
4
4
5
6
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne iMarc 9550 DS3

  • Page 1: Table Of Contents

    ® iMarc 9550 DS3 Probe Installation Instructions Document Number 9550-A2-GN10-00 September 2005 Contents Software and Firmware License Agreement ..........Product Documentation Online ..............Unpacking and Inspecting the Equipment ............ Installing the Brackets for Rack Mounting ............. Installing in a Rack ..................
  • Page 2: Software And Firmware License Agreement

    Paradyne or its authorized distributor or reseller under the following terms and conditions: 1. Ownership: The Software is the sole property of Paradyne and/or its licensors. The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
  • Page 3: Product Documentation Online

    SNMP traps, and RMON in iMarc SLV CSU/DSUs and routers. iMarc SLV Operations Guide (9000-A2-GB33-30) – Explains how to operate and troubleshoot iMarc SLV CSU/DSUs and routers. To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000.
  • Page 4: Unpacking And Inspecting The Equipment

    Unpacking and Inspecting the Equipment HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative.
  • Page 5: Installing In A Rack

    19-inch (483 mm) Rack Mount 23-inch (584 mm) EIA and Bay Networks Rack Mount 05-17709 23-inch (584 mm) Nortel Rack Mount Installing in a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes Procedure...
  • Page 6: Connecting To Power

    3. Insert and tighten the screws in the top screw positions, then tighten the bottom screws. Connecting to Power The Probe requires a 120 VAC, 60 Hz power source. Procedure To connect the 9550 DS3 Probe to power: 1. Connect a ground wire to the grounding screw on the front of the Probe. S U B S C R I B E R N E T W...
  • Page 7 3. Plug the socket end of the power cord into the power receptacle on the back of the Probe. 4. Plug the power cable into a 120 VAC, 60 Hz outlet. 05-17708...
  • Page 8: Connecting The Subscriber Port

    Connecting the Subscriber Port The Subscriber port connects to your DTE, such as a router. Procedure To connect the Subscriber port: 1. If clearance at the front of the Probe is limited, attach right-angle BNC adapters to the ends of two BNC cables. 2.
  • Page 9: Connecting To The Ds3 Network

    Connecting to the DS3 Network The Network port connects to the packet network . Procedure To connect the Network port: 1. If clearance at the front of the Probe is limited, attach right-angle BNC adapters to the ends of two BNC cables. 2.
  • Page 10: Connecting The Ethernet Port

    7. If the cable length is longer than 100 feet (30 meters), set the LBO on the T3 Network Interface Options configuration screen to Long. The default is Short. See the iMarc SLV Configuration Reference. Connecting the Ethernet Port The Ethernet port provides a 10/100BaseT connection that can be used for Telnet, FTP, and SNMP access to the Probe.
  • Page 11: Connecting The Modem Port

    Connecting the Modem Port The Probe supports asynchronous terminal interface sessions over its integral modem. Procedure To connect the Modem port: 1. Plug one end of an RJ11 telephone cable into the Modem port. 2. Plug the other end of the cable into an RJ11 telephone jack. S U B S C R IB E R N E T W...
  • Page 12: Connecting The Console Port

    Connecting the Console Port The Console port can be used to connect a VT100-compatible terminal or a PC with terminal emulation software, providing direct access to the asynchronous terminal interface. Procedure To connect the Console port to a terminal or PC: 1.
  • Page 13: Using The Asynchronous Terminal Interface

    Using the Asynchronous Terminal Interface The Probe should operate using the default (factory-set) configuration options, with exception to the changes specified in these installation instructions. Refer to the following table for help in navigating through the menus. Press the . . . To .
  • Page 14: Menu Hierarchy

    Menu Hierarchy The Menu Hierarchy shows the organization of the Probe’s asynchronous terminal interface screens. Status System and Test Self-Test Results Status Last System Reset Health and Status Test Status IP Path Device Name Connection Status IP Address Status Discovery Source PVC Connection Source and Destination ATM Link, VPI, Status...
  • Page 15 Configuration System Class of Service Definitions Monitored Protocol Definitions Service Level Verification General Network Physical VPI, VCI Records T3 User Ports Physical VPI, VCI Records PVC Connections Source and Destination Link, VPI, VCI, Management Type IP Subnet List Add and Display Local Subnets IP Path List Add and Display Static Paths Management and...
  • Page 16: Saving Configuration Options

    Saving Configuration Options Procedure To save a configuration option change: 1. Press Ctrl-a to switch to the function keys area at the bottom of the screen. 2. Type s or S (Save) and press Enter. The Save Configuration To menu appears. 3.
  • Page 17: Emi Notices

    CE Marking When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www.paradyne.com. Select Library → Technical Manuals → CE Declarations of Conformity.
  • Page 18: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
  • Page 19: Warranty, Sales, Service, And Training Information

    Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
  • Page 20 *9550-A2-GN10-00* *9550-A2-GN10-00*...

Table of Contents