Paradyne FrameSaver SLV 9664 Installation Instructions Manual

Hide thumbs Also See for FrameSaver SLV 9664:

Advertisement

Quick Links

FrameSaverr SLV 9664
Installation Instructions
Document Number 9664-A2-GN10-00
March 2000
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select Library →Technical Manuals → FrameSaver Frame Relay Devices.
Select the following document:
9664-A2-GB20
FrameSaver SLV 9664 User's Guide
To order a paper copy of a Paradyne document:
H
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
H
Outside the U.S.A., call 1-727-530-8623
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne FrameSaver SLV 9664

  • Page 1 It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Library →Technical Manuals → FrameSaver Frame Relay Devices.
  • Page 2: Package Checklist

    Power cord appropriate for the wall-plug standard in your country (depends on model ordered). (NT1) network cable FrameSaver SLV 9664 Quick Reference (Document No. 9664-A2-GL10) Additional cables may be ordered. See Cables You Can Order on page 3 when ordering cables.
  • Page 3: Safety Instructions

    Cables You Can Order Feature Part If connecting to . . . Order a . . . Number Number LAN adapter Adapter DB25 3100-F1-920 002-0069-0031 plug-to-8-position modular receptacle COM Port-to-LAN 3100-F2-910 035-0315-1431 adapter cable (14 feet – 4.3 meters) Equipment with X.21 DTE adapter cable, 3100-F1-571 035-0302-0131...
  • Page 4: Installing The Power Supply And Cord

    Installing the Power Supply and Cord 1. Insert the power supply’s 4-prong plug into the POWER jack. When inserting the plug at the rear of the FrameSaver unit, align the plug with the notch above the POWER jack. Make sure the locking tab snaps securely into the jack.
  • Page 5 Connecting the COM Port to an Async Terminal or PC The FrameSaver unit must first be directly connected to a PC or asynchronous terminal (providing VT100 terminal emulation) to set up access and management of the unit. 1. Configure the VT100-compatible terminal or PC to be compatible with the access unit: –...
  • Page 6: A Quick Guide To Configuration

    A Quick Guide to Configuration The FrameSaver unit should operate using the default (factory-set) configuration options, with exception to the changes specified in these installation instructions. Refer to the following table for help in navigating through the menus. Press the . . . To .
  • Page 7 Network Operations Center (NOC) router (for management by the Network Service Provider). Multiple management PVCs then connect the central site unit to the remote site units using Paradyne’s proprietary PVC multiplexing method (embedded DLCIs).
  • Page 8: Verifying That Self-Test Passed

    Verifying that Self-Test Passed 1. Follow this menu selection sequence from the Main Menu and press Enter after each selection: Main Menu → Status → System and Test Status 2. Check the Self-Test Results column (in the center of the System and Test Status screen).
  • Page 9: Configuring Physical Interfaces

    Configuring Physical Interfaces The network connection supports leased-line service with a BRI S/T interface via an 8-position unkeyed modular jack that is connected to an external NT1. The data port interface supports three different port types: EIA-530, V.35 and X.21. If your application does not use a V.35 interface, then the Port Type setting needs to be changed.
  • Page 10: Automatic Configuration

    Automatic Configuration The FrameSaver unit provides several automatic configuration features. Frame Relay Discovery and configuration is one of these features. Main Menu → Auto-Configuration The default discovery mode is 1MPort. In this mode, for each DLCI discovered on the network, a multiplexed network DLCI and a standard data port DLCI will be configured and connected, and a Management PVC will be embedded in the network DLCI.
  • Page 11: Connecting To The Network

    Connecting to the Network Now that the FrameSaver unit is set up, the unit can be connected to the network. 1. Insert the 8-pin connector of the network cable into the network interface, NET (S/T). 2. Insert the other end of the cable into the S/T interface of the NT1. S/T Interface (ITU-T I.430) 00-16677...
  • Page 12: Setting Up Service Provider Connectivity At The Central Site

    Setting Up Service Provider Connectivity at the Central Site When management needs to be set up between a service provider’s customer and its network operations center (NOC), a non-multiplexed DLCI must be configured to carry management data between the customer’s central site and the NOC console. This requires that a frame relay discovered DLCI needs to be modified.
  • Page 13: Configuring Snmp Trap Managers And Traps

    Configuring SNMP Trap Managers and Traps Once the FrameSaver unit is connected to the network, SNMP trap managers and SNMP traps can be configured. To enter SNMP managers and configure traps: 1. Select SNMP Traps. Main Menu → Configuration → Management and Communication → SNMP Traps 2.
  • Page 14: Connecting To The Dte (Router Or Frad)

    Connecting to the DTE (Router or FRAD) 1. Connect the appropriate cable to the Port (To DTE) connector. – If the DTE interface type is EIA-530A, the DTE can be directly connected to the Port (To DTE) connector. – If the DTE interface type is V.35 or X.21, a V.35 or X.21 adapter cable is required.
  • Page 15 Check that Data is Being Received 1. Return to the Main Menu. 2. Select Performance Statistics, and select an interface’s frame relay statistics. Main Menu → Status → Performance Statistics → Frame Relay → Net1-FR1 3. Verify that the Frames Received and Characters Received counts under the Frame Relay Link statistics are incrementing, and there are no errors under the Frame Relay LMI statistics.
  • Page 16 FrameSaver 9664 Front Panel 9664 FrameSaver FrameSaver ® NETWORK PORT 00 -16658 FrameSaver 9664 Rear Panel 00-16657...
  • Page 17: Important Safety Instructions

    Low Voltage (SELV) output less than 240 VA available, certified for use in the country of installation. Paradyne power supply part number 327-0107-0031 is recommended. This power supply includes a special mating connector for connection to this equipment. 5. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
  • Page 18 10. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions: — Never install telephone wiring during a lightning storm. — Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. —...
  • Page 19 CE Marking When the product is marked with the CE mark, this demonstrates full compliance with the following European Directives: Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68/EEC.
  • Page 20: Warranty, Sales, Service, And Training Information

    Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.

Table of Contents