4.14 Setting The Inherent Safety

LXL V1.20
MX RN 20:00s
SYSTEM
PRESS 125
SAFE PSI
On = 155
Off = 145
Ax = 125

4.15 Setting the Gate Locking Device

4.15.1 Self Latching Lock Parameter

UNLOCK?
Switch-Off
B&B ARMR
A Division of B&B Roadway and Security Solutions
1. Press the ESC button to return to the
main menu.
2. Engage the drive wheels on the drive
rail. Open and Close the operator
using the 3 button control station.
The screen on the left will appear.
3. While the gate is running, pay
attention to the SYSTEM PRESS
value. This is the amount of pressure
required to move the gate.
4. Stop the gate operator and press the
ESC button to enter the main menu.
5. Select 'Set Param' and use the UP
arrow key to scroll to SAFE PSI.
6. Press OK to activate the cursor.
Enter the On value (SYSTEM
PRESS+30), then the Off value (On-
10).
7. Press OK to save and return to the
main menu.
1. From the main menu, select 'Set
Param'.
2. UNLOCK will be the first user
parameter, press OK.
3. The S on Switch will start flashing
4. Use the UP grey arrow key to change
Off to On
5. Press OK to save
Now you will need to wire in the self-
latching lock as shown on page 40