Installation and Operations Manual — LXL Gate Operator

4.12 Turning ON / OFF The Timer To Close

AutoClose
Activated
00:00s
00:00s

4.13 Setting The Timer To Close

AutoCLS
T =20:00s
Ta = 00:00
B&B ARMR
A Division of B&B Roadway and Security Solutions
OPEN
CLOSE
STOP
Bottom number
shows elapsed time.
Bottom number shows
elapsed time.
With the unit powered down and the gate
in the closed position, locate the supplied
3 button control station and do the
following (in order):
1. Press and hold the STOP button
2. While holding the STOP button,
press and hold the CLOSE button.
3. While holding the STOP and CLOSE
buttons, press and release the OPEN
button.
4. Release the CLOSE button, then the
STOP button.
5. Trigger the open limit switch. If the
timer is on, you will see the screen to
the left.
6. Repeat step 1 to toggle the timer off
NOTE: The AutoClose screen will not be
visible if the timer is turned off
There is a 3 minute window with which
to turn the timer to close on or off each
time the operator power is turned on.
1. From the main menu, select 'Set
Param'.
2. Use the UP arrow to scroll to the
AUTO CLS screen and press OK.
3. Press OK again to activate cursor.
Use the arrow keys to set the desired
time.
4. Press OK to save
Note: s = seconds, m = minutes, h =
hours
21
0054-9001UL Revision A2