Installation and Operations Manual — LXL Gate Operator

Setting The Date And Time (optional, not required)

>Stop
Set Param
Set Clock
Prg Name
Set Clock
Su 00:00
YYYY-MM-DD
2003-01-01

4.11 Setting The Max Run Timer

MAX RUN
T =20:00
Ta=00:00
B&B ARMR
A Division of B&B Roadway and Security Solutions
Bottom number
shows elapsed time.
1. Turn power on. Date and time will be
flashing. Press the ESC key.
2. This is the main menu. Use the UP
and DOWN arrow keys to select 'Set
Clock', and press the OK button.
3. Press OK again. A cursor flashes
under the parameter to be changed.
4. Use the UP and DOWN arrow keys
to change the value. Use the LEFT
and RIGHT arrow keys to move
between lines.
5. Press OK when finished.
NOTE: *Time format is military time
only.
1. From the main menu, select 'Set
Param'.
2. Use the UP arrow to scroll to the
MAX RUN screen and press OK.
3. Press OK again to activate cursor.
4. Use the arrow keys to set the desired
time.
5. Press OK to save
Note: Max run time = gate length ÷ gate
speed * 2 + 5 seconds