Creating/Editing programs.
The following are three simple programming examples of entering programs via the Model 620A
front panel.
Single Channel:
CH1 is most commonly used as the temperature control channel. In this mode the Ch2 Guarantee
Soak, Setpoints and Dev are not displayed or accessible.
Program example
Graph
Entering program
Two Channel: (Not Shown)
Ch1 is the temperature control channel, and CH2 can be used as a second temperature or other
process related control function. Some common two channel systems are Temp/Temp such as
thermal shock chambers. Temp/Relative Humidity using either wet bulb/ Dry Bulb or electronic
sensors. The Model 620A internally contains the tables for WB/DB conversion, and Temp
compensation for the Vaisala HMM30 RH sensor to providing direct % RH setpoint entry and
process display values. Temp/Altitude. The Model 620A provides the conversion of altitude in feet
from the popular Omegadyne PX41 series pressure sensors for 1-15 and 0-20PSIA.
Program Example
Entering Program
FastTRAC & FastTRAC PassThru.: (Not Shown)
When placed in the FastTRAC mode of operation and implementing the pantented ThermoBoost
feature. The Model 620A provides the ability to accelerate the device under test to the
programmed test temperature and offers exceptional product temperature control.
Program Example
Entering Program