12. ABSOLUTE POSITION DETECTION SYSTEM

12.8 Communication-based absolute position transfer system

12.8.1 Serial communication command

The following commands are available for reading absolute position data using the serial communication
function. When reading data, take care to specify the correct station number of the servo amplifier from
where the data will be read.
When the master station sends the data No. to the slave station (servo amplifier), the slave station returns
the data value to the master station.
(1) Transmission
Transmit command [0] [2] and data No. [9] [1].
(2) Reply
The absolute position data in the command pulse unit is returned in hexadecimal.

12.8.2 Absolute position data transfer protocol

(1) Data transfer procedure
Every time SON turns on at power-on or like, the controller must read the current position data in the
servo amplifier. Not performing this operation will cause a position shift.
Time-out monitoring should be performed by the controller.
Data 32-bit length (hexadecimal representation)
Servo amplifier
Command [0][2] + data No.[9][1]
Absolute position
data acquisition
Absolute position data return
12 - 32
SON on
RD on
Absolute position data
command transmission
Position command start
Controller
Watch dog timer
Current position
acquisition
Current value
change