Mitsubishi MR-J4-10A Instruction Manual page 192

Melservo j4 servo amplifier
Table of Contents

Advertisement

5. PARAMETERS
No./symbol/
Setting
name
digit
PA02
_ _ x x
Regenerative option
*REG
Select the regenerative option.
Regenerative
Incorrect setting may cause the regenerative option to burn.
option
If a selected regenerative option is not for use with the servo amplifier, [AL. 37
Parameter error] occurs.
00: Regenerative option is not used.
01: FR-RC-(H)/FR-CV-(H)/FR-BU2-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required.)
08: MR-RB31
09: MR-RB51 (Cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (Cooling fan is required.)
80: MR-RB1H-4
81: MR-RB3M-4 (Cooling fan is required.)
82: MR-RB3G-4 (Cooling fan is required.)
83: MR-RB5G-4 (Cooling fan is required.)
84: MR-RB34-4 (Cooling fan is required.)
85: MR-RB54-4 (Cooling fan is required.)
91: MR-RB3U-4 (Cooling fan is required.)
92: MR-RB5U-4 (Cooling fan is required.)
FA: When the supplied regenerative resistor or a regenerative option used with the
_ x _ _ For manufacturer setting
x _ _ _
For the servo amplifier of 100 W, a regenerative resistor is not used.
For the servo amplifier of 0.2 kW to 7 kW, the built-in regenerative resistor is
used.
The supplied regenerative resistor or a regenerative option is used with the
servo amplifier of 11 kW to 22 kW.
When you use FR-RC-(H),FR-CV-(H) or FR-BU2-(H), select "Mode 2 (_ _ _ 1)"
of "Undervoltage alarm detection mode selection" in [Pr. PC27].
servo amplifier of 11 kW to 22 kW is cooled by a cooling fan to increase
regenerative ability.
Function
5 - 13
Control
Initial
value
mode
[unit]
P
S
T
00h
0h
0h