Download Print this page

Philips TDA8002C Datasheet page 3

Philips ic card interface data sheet

Advertisement

Philips Semiconductors
IC card interface
QUICK REFERENCE DATA
SYMBOL
Supplies
V
supply voltage
DD
I
supply current
DD(lp)
I
supply current
DD(idle)
I
supply current
DD(active)
Card supply
V
output voltage
CC(O)
General
f
card clock frequency
CLK
t
deactivation sequence duration
de
P
continuous total power dissipation
tot
TDA8002CT/x
TDA8002CG
T
ambient temperature
amb
1999 Oct 12
PARAMETER
CONDITIONS
low-power
Idle mode; f
= 10 MHz
CLKOUT
active mode; V
= 5 V;
CC(O)
f
= 10 MHz
CLKOUT
f
= LOW; I
= 100 A
CLK
CC
f
= 5 MHz; I
= 10 mA
CLK
CC
f
= 5 MHz; I
= 55 mA
CLK
CC
active mode; V
= 3 V;
CC(O)
f
= 10 MHz
CLKOUT
f
= LOW; I
= 100 A
CLK
CC
f
= 5 MHz; I
= 10 mA
CLK
CC
f
= 5 MHz; I
= 55 mA
CLK
CC
active mode for V
= 5 V
CC
I
< 55 mA; DC load
CC
I
= 40 nAs; AC load
CC
active mode for V
= 3 V
CC
I
< 55 mA; DC load
CC
I
= 40 nAs; AC load
CC
T
= 25 to +85 C
amb
T
= 25 to +85 C
amb
3
Product specification
TDA8002C
MIN.
TYP.
MAX.
3.0
6.5
150
5
8
50
140
8
50
140
4.6
5.4
4.6
5.4
2.76
3.24
2.76
3.24
0
12
60
80
100
0.56
0.46
25
+85
UNIT
V
A
mA
mA
mA
mA
mA
mA
mA
V
V
V
V
MHz
s
W
W
C

Advertisement

loading

This manual is also suitable for:

Tda8002ct/a/c1Tda8002ct/c/c1Tda8002cg/c1