Lacunza Vulcano 7T E3 E/E Instruction Book page 12

Multi-fuel cooker
Table of Contents

Advertisement

With the fire stabilised, use the log loads
and primary draught regulator "E", and
draught regulator "F" on the Vulcano
7TE3 model, to produce greater or lesser
heat output. Adjust the Flue damper "G"
as required.
F
A
E
Figure 8
A: Firebox door handle
B: Oven door handle
C: Direct draught rod
C1: open
C2: closed
D: Oven thermometer
Warning: During the first firing of the
cooker, you may experience fumes and haze
caused by the curing process. This is quite
normal but we do recommend that you open
the windows in the room and ventilate the
room thoroughly for the first few hours of
operation.
You may also notice a small amount of water
around the cookers which will be caused by
B
G
C
D
E: Primary-air inlet regulator
E1: open
F: Secondary-air inlet regulator
F1: open
G: Flue damper
the moisture from the wood on the first
lighting. This moisture will cease after the
first few firings of the appliance. If it does
not, then check the gas flue draught (length
and diameter of the chimney, chimney
insulation, airtightness) and the dampness of
the wood used.
The first time the cooker is lit, the fire
should be gentle to allow the parts of the
appliance to dilate and dry.
C1 open
E1 open
F1 open
E1 open
F1 open
E2: closed
F2: closed
C2 closed
E2 closed
F2 closed
E2 closed
F2 closed
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vulcano 7t e/e

Table of Contents