Boiler Installation; Boiler Size - Baxi LUNA HT 1.450 Installers And Users Instructions

Wall-mounted condensing boilers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 63
IT
DE
GB

10. Boiler installation

CZ
HU
RO

11. Boiler size

To avoid damaging metal, plastic and rubber parts, use only neutral cleaners, i.e. non-acid
and non-alkaline such us SENTINEL X100 and FERNOX heating circuit protective. To use
this product proceeding strictly in accordance with the maker's directions.
Remember that the presence of foreign matter in the heating system can adversely affect the
operation of the boiler (e.g. overheating and noisy operation of the heat exchanger).
Failure to observe the above will render the guarantee null and
Decide upon the boiler location, then tape the template on the wall.
Connect the pipework to the gas and water inlets prearranged on the template lower bar.
If you are either installing the boiler on a pre-existent system or substituting it, we suggest you also
fit settling tanks on the system return pipework and under the boiler to collect the deposits and scaling
which may remain and be circulated in the system after the purge.
When the boiler is fixed on the template connect the flue and air ducts (fittings supplied by the ma-
nufacturer) according to the instructions given in the following sections.
Connect the condensate outlet to the siphon supplied with the boiler. Connect the siphon to a drain,
making sure there is a continuous slope. Horizontal sections must be avoided.
DRILL HOLES WITH A Ø12 BIT, FIT THE MASONRY
PLUGS AND THE SCREWS PROVIDED
N.B. INCLUDE CONDENSATE DRAIN POINT
BOILER WIDTH 600
Figure 5
Figure 6
MR: G 1 heating flow
GAS: G3/4 gas inlet to the boiler
RR: G 1 heating return
SC: condensation drain
73 73
void.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna ht 1.650Luna ht 1.550

Table of Contents