3.5.2 Setting the daily
IT
times for domestic hot
water mode operation
DE
GB
3.6 Setting the minimum
CZ
central heating tempe-
HU
RO
3.7 Table of user-settable para-
- As supplied by the factory the appliance is set up with the domestic hot water function always
enabled and the domestic hot water programming function disabled.
The instructions for enabling this program are given in chapter 17, which is addressed specifically
to installers (parameter H91).
If the program is enabled program lines from 31 to 36 must be set up as described in heading 3-
5.1.
- press either of the
- press these keys until the display shows P5, referring to the temperature to be set;
rature
- press the
This operating mode is enabled when minimum temperature central heating mode
or when the daily central heating program does not require heat
N.b – With the outdoor sensor probe connected, parameter P5 can be used to set the minimum
room temperature in the premises to be heated.
Parameter
Parameter description
meters
N.
P1
Time of day setting
P5
Minimum central heating temperature setting (°C)
P11
Start of first daily period of automatic central heating
P12
End of first daily period of automatic central heating
P13
Start of second daily period of automatic central heating
P14
End of second daily period of automatic central heating
P15
Start of third daily period of automatic heating
P16
End of third daily period of automatic central heating
P31
Start of first daily period of domestic hot water production (*)
P32
End of first daily period of domestic hot water production (*)
P33
Start of second daily period of domestic hot water production (*)
P34
End of second daily period of domestic hot water production (*)
P35
Start of third daily period of domestic hot water production (*)
P36
Fine End of third daily period of domestic hot water production (*)
P45
Reset of daily central heating and domestic hot water production programs (factory
settings). Press the - + keys together for about 3 seconds; the number 1 appears on
the display. Confirm by pressing either of the
Note: Parameters from P31 to P36 can be displayed only if the domestic hot water program has been
enabled as described in chapter 17 for the attention of the installer (parameter H91).
keys to access the programming function;
keys to set the temperature required.
68 68
.
keys
is activated
"
"
Factory
Range
setting
———-
0...23:59
25
25..80
6:00
00:00...24:00
22:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
24:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0
0...1