Pressure Relief Procedure
6.
Turn the prime valve down. Put drain
tube in a pail. Leave prime valve in the
down (drain) position until you are ready
to spray again.
7.
If you suspect the spray tip or hose is
clogged or that pressure has not been
fully relieved:
a.
VERY SLOWLY loosen the tip
guard retaining nut or the hose end
coupling to relieve pressure
gradually.
b.
Loosen the nut or coupling
completely.
c.
Clear hose or tip obstruction.