Blankom EMU-8500 Installation Instructions Manual

Mpeg4 hd ip

Advertisement

Quick Links

MPEG4 HD to IP Encoder
Installation and operation Instructions
EMU 8500 Series
8 ... 24 Inputs depending on ordered device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMU-8500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blankom EMU-8500

  • Page 1 MPEG4 HD to IP Encoder Installation and operation Instructions EMU 8500 Series 8 … 24 Inputs depending on ordered device...
  • Page 2 MPEG4 HD IP Encoder User Manual About This Manual To whom it may concern This user manual has been written to help people who have to use, to integrate and to install the product. Some chapters require some prerequisite knowledge in electronics and especially in broadcast technologies and standards.
  • Page 3: Table Of Contents

    MPEG4 HD IP Encoder User Manual Table of Content ............................2 BOUT ANUAL ..........................1 HAPTER NTRODUCTION 1.1 P ............................ 1 RODUCT VERVIEW 1.2 K ) ..................1 EATURES UMBER OF DEPENDING ON MODEL 1.3 S ............................2 PECIFICATIONS 1.4 B ............................
  • Page 4: Chapter 1 Introduction

    Usually the DATA GbE Port needs an IP address- otherwise the Switch or the receivers (i.e. IPTV STB's) cannot locate the source of the streams. Author: RRi - 1 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 5: About This Manual

    English and Chinese language function Ethernet software upgrade Dimension(W×L×H) 482mm×410mm×44mm Approx weight Environment 0~45℃(work);-20~80℃(Storage) Miscellaneous AC 110V± 10%, 50/60Hz, AC 220 ± 10%, Power requirements 50/60Hz Power consumption Author: RRi - 2 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 6: Block Diagram

    MPEG4 HD IP Encoder User Manual 1.4 Block Diagram Author: RRi - 3 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 7 Power supply and Grounding Pole 8…24 HDMI input Reset Key Data Port Indicator ASI output port BNC(Optional) DATA Ports (1 or 2 GbE port for IP stream output) NMS/CAS one 100BaseT Author: RRi - 4 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 8: Chapter 2 Installation Guide

    Floor limiting resistance: 1MΩ (Floor bearing should be greater than 450Kg/㎡) 5~40°C (sustainable ),0~45°C (short time), Environment Temperature installing air-conditioning is recommended 20%~80% sustainable 10%~90% short time Relative Author: RRi - 5 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 9: Grounding Requirement

    I.e. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx can be 1 to 254 except 252 to avoid an IP conflict). Author: RRi - 6 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 10: Encoder Setup

    This encoder support up to 2 / 3 / 4 / 5 / 6 modules with 8 / 12 / 16 / 20 / 24 HDMI inputs. From the menu on the left side of the webpage, clicking “Module1-6”, displays the information of each encoding channel: Author: RRi - 7 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 11 From the menu at the upper side of the webpage by using “Stream select” displays the interface where the user can select program(s) to multiplex out and modify program info.:, Author: RRi - 8 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 12 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as following: Select the Input channels to process them to the output. By expanding the single encoded services you'll get the default information and Author: RRi - 9 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 13 Similarly, you can remove the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs Author: RRi - 10 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 14 As soon as the Input encoded services have been pushed to the output, the SPTS stream addresses are defined by default with address and port numbers which can of course modiified to your local needs later. Author: RRi - 11 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 15 VBR streams to the IPTV world. Parameters→ OSD On Screen Display as Overlay : Selecting ‘OSD’, will show the interface to configuration the OSD parameters Author: RRi - 12 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 16 Select the text color and background color Put your caption anywhere Enter your text here Figure-10 Importand Note: Currently this text-insertion can be only configured if you are using the FireFox browser. Author: RRi - 13 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 17 NMS. Be careful, not to lose the user/PW combination otherwise you are not able to login later and need to RESET the unit by the front panel Author: RRi - 14 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 18 System → Firmware: Selecting “Firmware”, will display the screen where to update firmware for the modulator. Example: Usually there are 3 Files to update: Author: RRi - 15 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 19 Please upgrade it on firmware page by selecting "Host" option. 3) DX224S_Encoder_v1.33.enc: Please upgrade it on firmware page by selecting "All Mod" option. You can upgrade them without considering a special sequence. 1): unrar/unzip the files first Author: RRi - 16 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 20 MPEG4 HD IP Encoder User Manual UPGRADE ! confirm 2) next file: Author: RRi - 17 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 21 MPEG4 HD IP Encoder User Manual last: Author: RRi - 18 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 22 NOW REBOOT by ON-OFF-ON Switch at the rear panel. But wait a few seconds before switching ON again. After upgrading the System, the overview shows the new version: Author: RRi - 19 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 23 Selecting “Date/Time” will show the menu to set date and time and NTP options for the device: System→ Log: Selecting “Log” will show the log interface to check or export the Kernel/System log. Author: RRi - 20 - Version 1.0 Date: 13. July 2017 EMU-8500-series-operation-instructions.docx...
  • Page 24: Chapter 4 Troubleshooting

    Owiesenkehre 1 D-22177 Hamburg - Germany Managing Director: Dipl.Ing. Riccardo Rossini Commercial Register: HRB 130657 / District Court Hamburg Web: www.blankom.de E-Mail: info@blankom.de Irenis-Direct Phone: +49 40 459747 Technical Hotline: +49 40 22864848 Author: RRi - 21 - Version 1.0 Date: 13.

Table of Contents