(such as translation, transformation or adaptation) without written permission from BLANKOM Digital GmbH. BLANKOM Digital GmbH reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of BLANKOM Digital GmbH to provide notification of such revision or change.
EQM 100 / EQM 101 / EQM 102 Edge-QAM General Description Edge-QAM EQM 100 is able to feed 24 QAM channels for additional services into distribution networks near the edge of the subscribers. For smaller networks the EQM 102 with 16 channels or the EQM 102 with 8 channels can be chosen.
EQM 100 / EQM 101 / EQM 102 Edge-QAM Reset After a restart or reset the EQM 10x is operating again after approx. 7 sec. All parameters are stored and the device will start with the last configuration. Signalling during restart: 1.
The default IP address for configuration is 192.168.200.20. Please keep in mind that you have to configure e.g. for the EQM 100 with 3 IP interfaces also three components. If you connect your browser with the IP-address 192.168.200.20 the following menu appears: Fig.
Page 8
EQM 100 / EQM 101 / EQM 102 Edge-QAM Fig. 5: Device Settings The Device Settings menu shows parameters that are common for all QAM channels. Fig. 6: Device Status The Device Status menu gives information about status parameters of the device.
Page 9
EQM 100 / EQM 101 / EQM 102 Edge-QAM Fig. 7: Channel Settings The Channel Settings menu allows the configuration of the QAM channels. QAM mode, symbol rate, center frequency and RF level is valid for a group of 4 QAM channels. Although grouped together each channel can be switched off individually.
Page 10
EQM 100 / EQM 101 / EQM 102 Edge-QAM Fig. 9: Logging The Logging menu lists all events of the logbook of the Edge-QAM. Fig. 10: Configuration NIT Processing The NIT menu allows the configuration of the NIT (Network Information Table) processing. If it is necessary to insert a new NIT into the transport stream the Edge QAM is able to receive a new NIT over the IP network and to replace it with the already existing NIT in the transport stream.
EQM 100 / EQM 101 / EQM 102 Edge-QAM Software Download Fig. 11: Software Upgrade The Upgrade menu allows the download of new software to the Edge QAM. The download procedure is given below: 1. Make connection from Egde QAM to the standard web browser of a PC (default IP address: 192.168.200.20)
Page 12
EQM 100 / EQM 101 / EQM 102 Edge-QAM Fig. 12: Download Status During the upgrade information of the download status are displayed for the user. Seite 12 (14) www.blankom-digital.de Rev. B...
EQM 100 / EQM 101 / EQM 102 Edge-QAM Miscellaneous History Revision Changes Page Author Date Rev. A First Release Geilert May 2008 Rev. B Minor Changes Dornemann June 2008 Blankom Digital GmbH TecCenter 31162 Bad Salzdetfurth Germany Phone +49 (0) 5063 / 2711 - 0...