Breaking The Welder And Generator Set - Kipor KDE180XW Operator's Manual

Air-cooled diesel welder and generator set
Table of Contents

Advertisement

(8) When the set is used only for the welding separately, the welding cable should
be removed or protected. When the set is used only for the welding separately,
the air switch should be turned off, or the power supply plug should unplugged to
avoid if from short-circuit.
(9) The reference for the current by using the electric welding rods in different
diameters
Diameters of Electric
1.6
2.0
Welding Rods (mm)
Welding Power
40-50
50-80
Supply (A)
3.7.3 Charge
(1) For the set with the electric start, the set is equipped with a power supply 12V
DC. The battery is charged through a regulator. After the battery is connected into
the start circuit, and after starting the diesel engine and the set is turned into the
running state, at this time, 12V circuit will charge the battery automatically.
(2) If the set is not in use for a long time, it is necessary to remove the connection
lines of the battery to prevent the battery form the electric leakage.
(3) Never connect the positive pole of the battery with the negative pole each
other. Otherwise it will damage the battery and the motor.
(4) Do not misconnect the positive pole of the battery with the battery. Otherwise
it will damage the battery and the motor.
(5)The flammable gas will be produced while charging the battery. The spark,
flame and cigarette should not be approached to the place of charging the battery.
In order to avoid that there is any spark produced nearby, firstly connect the
battery with the charging conductor and then with the motor. At the time of
disconnection, firstly disconnect the motor cable.
-
2.5
3.2
4
60-100
100-140
150-180
-
3.8 Braking the Welder and Generator Set
3.8.1. Remove the load of the welder and generator set.
3.8.2. Turn off the air switch of the welder and generator set.
3.8.3. Set the speed handle of the engine to RUN position. Carry out the unload
operation of the diesel engine for three minutes. Do not brake the diesel engine
suddenly because this may make that the temperature goes up abnormally to
cause the blocking-up of the oil nozzle and the damage of the diesel engine.
(1) Press the braking handle downwards.
(2) When using the electric starter, turn the key to OFF .
(3) Set the fuel switch handle to S position.
(4) Slowly draw out the recoil handle till you feel the pressure (i.e., at this point of
the compression stroke, the suction and exhaust valves are closed.). Stop the
handle at this position. In such a way, when the engine is not in use, the rusting
can be prevented.
Fuel Switch
1. When the speed handle is set at stop position and
CAUTION
the diesel engine is still in operation, it is possible to
stop the diesel engine either by setting the fuel switch
to OFF position or by unfastening the high pressure
oil pipe nut. Do not brake the diesel engine by using
the pressure reduction handle.
2. It is not allowed that the set stops with the load. It is
necessary to firstly remove the load and then to stop
the set.
-
Unfasten this nut
(high pressure oil pipe nut)
-

Hide quick links: