Secur Et - Veb Eyebolt; Dimensions - Tannoy VSXNET Series Operation Manual

High-performance subwoofers
Hide thumbs Also See for VSXNET Series:
Table of Contents

Advertisement

11. SECUR ET – VEB Eyebolt
11. SECUR ET – VEB Eyebolt
Tannoy VSX subwoofers can be flown with high quality VEB M10 eyebolts with collar to BS4278:1984. The
loudspeaker is equipped with internal angle plates, which also double as the flying points, and directly accept
VEB M10 eyebolts.
To install the VEB M10 eyebolts, remove the original M10 counter sunk screws from the locations where VEB M10
eyebolts are to be installed. Replace these counter sunk M10 screws with the VEB M10 eyebolts.
Important: It is imperative for safety reasons that two eyebolts, each linked to two independently fixed straps,
are used per cabinet. VEB eyebolts should be installed into the fly points as indicated in the following illustrations.
Never suspend one enclosure from another to form an array or cluster using these fittings. Never attempt to use
formed eyebolts (formed from a steel rod and bent into an eye).

12. Dimensions

VSXNET 12.2BP
400.0
[15.75"]
24
VSXNET Subwoofer Operation Manual rev 2.0.0
830.0
[32.68"]
750.0
[29.53"]
450.0
[17.72"]
320.0
[12.60"]
720.0
[28.35"]
Fly Points
Fly Points