WARNING CAUTION OPERATION *NOTE: Please check www.windcrestcnp.com for revisions before doing any custom work. ELECTRICAL REQUIREMENTS Important: all local codes and ordinances. UIX3019S / UIX3619S - 480W, 5 Amps FEDERAL COMMUNICATION COMMISSION INTERFACE STATEMENT...
www.windcrestcnp.com MODELS: PARTS SUPPLIED HARDWARE PACKAGE CONTENTS Light Bulb Removal #8 x 1/2” (12) Suction Cup (1) 3/16” x 3/8” (10) Wire Caps (3) RF Remote Control (1) Remote Holder (1) M4 x 6mm (8) PARTS NOT SUPPLIED - Cable connector (if required by local codes)
Page 7
Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
Page 8
www.windcrestcnp.com bottom should be no less than 26”. 36”. i n . a x . ” m ” m Vertical Ducting: 8” round minimum Horizontal Ducting: ” DAMAGE-SHIPMENT / INSTALLATION: DUCTING installation. customer. and installer.
Page 9
WARNING FIRE HAZARD Some Ducting Options side wall cap w/ gravity damper side wall cap w/ gravity damper Soffit or crawl space 8” round or 3-1/4”x10” rect. 8” round horizontal ducting vertical ducting Roof Pitch w/ Flashing & Cap 8” round vertical ducting...
Page 11
ELECTRICAL WARNING how and background. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: Cable Lock: Cable Lock...
Page 12
Continue to Step 4 after preparation is completed. WARNING: Make sure the surface you are securing the liner to is capable of holding the weight of UIX3019S & UIX3619S. Failure to do so may cause personal injury or damage to cooking surface or counter.
Page 15
Rect. Round At this point, install the one piece liner into the cabinet by following the steps on Page 10, Step 4. After the liner installation, continue to page 14.
Page 16
www.windcrestcnp.com 10. (Rectangular Ducting) 10. (Round Ducting) Horizontal ducting preparation is now complete. Refer to Page 10, Step 5 to complete installation.
Page 17
Blower On/Off Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. CFM Select™...
Page 18
www.windcrestcnp.com Baffle Filter Clean Reminder A set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle- Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use.
Page 19
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compli- ance could void the user’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral device.
www.windcrestcnp.com SURFACE MAINTENANCE: illuminated on the liner controls Hood Model: Part No. Qty. to Order Cleaning the Grease Tray Removing the Grease Tray...
REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Note: Bottom View...
Page 22
TROUBLESHOOTING PROCEDURES FOR UIX3019S / UIX3619S Issue Cause What to do disconnected. blower is not down. 2. Close all the windows and doors to eliminate 1. Filter is loose. RF Remote control does not 2. Poor communication with the liner.
MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS UIX3019S, UIX3619S CIRCUIT DIAGRAM CFM Select™ By default the maximum blower CFM is set to 600.
7.) Service to replace consumable parts (i.e. Light Bulbs, Heat Lamps, Filters). 8.) Expenses for travel and transportation if appliance is located in a remote area. You may also write to us at: Wind Crest™ by CNP Industries, Inc. 351 Thor Place Brea, CA 92821 (877) 387-6721 This warranty applies to appliances used in residential applications only.
Need help?
Do you have a question about the UIX3019S and is the answer not in the manual?
Questions and answers