Module Replacement Procedures; General Replacement Information; Anti-Static Precaution; Figure 11 Chassis Ground Wiring Diagram - Motorola PDR 3500 Basic Service Manual

Portable repeater
Hide thumbs Also See for PDR 3500:
Table of Contents

Advertisement

AC Inlet
(Viewed from
Underside)
Module Replacement
Procedures
General Replacement
Information
WARNING: When wearing a Conductive Wrist Strap, be careful near sources of high voltage.
!
The good ground provided by the wrist strap will also increase the danger of lethal shock
from accidentally touching high voltage sources.

Anti-Static Precaution

CAUTION: DO NOT insert or remove station modules with power applied. This may result in
!
damage to the modules.
68P81093C75-O
BROWN
ORANGE
Lock
Washers
GRN/YEL

Figure 11 Chassis Ground Wiring Diagram

Station modules suspected of being faulty must be replaced with
modules known to be in good condition in order to restore the station
to proper operation. The following procedures provide instructions
for replacing each of the station modules and performing any
required post-replacement adjustments or programming.
The station circuitry contains many C-MOS and other static-
sensitive devices. When servicing the equipment, you must take
precautionary steps to prevent damage to the modules from static
discharge. Complete information on prevention of static protection
is provided in Motorola publication number 68P81106E84,
available through the Accessories and Aftermarket Division.
Some additional precautions are as follows:
A wrist strap (Motorola part number RSX4015A,
or equivalent) should be worn while servicing the
equipment to minimize static buildup.
September 27, 2000
Power Supply
Output
Input
Neg Pos H
N
Gnd
Nuts
GRN/YEL
Ring Lugs
Chassis
Ground Stud
MAEPF-27099-O
9-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents