Required Test Equipment - Motorola PDR 3500 Basic Service Manual

Portable repeater
Hide thumbs Also See for PDR 3500:
Table of Contents

Advertisement

Required Test Equipment

IMPORTANT!
9-22
The transmitter circuitry is exercised by injecting and measuring
signals using a Motorola R2670 Communications Analyzer (or
equivalent), and analyzing the Bit Error Rate using the RSS.
Measured values outside the acceptable range indicate a faulty
module; values within range verify proper operation of the above
modules and circuitry.
The following test equipment is required to perform the procedure:
Motorola R2670 Communications Analyzer with
ASTRO CAI Option (or equivalent)
PC running Radio Service Software (RSS)
program
Female N-type to Female N-type coaxial cable
Dummy Load (50Ω, station wattage, or higher).
Required for repeater stations only.
If the station operates as a repeater, the transmit output from
the station must be connected to a dummy load to prevent over-
the-air broadcast during receiver testing.
Step 1. Proceed to ASTRO Bit Error Rate Report (located in
Chapter 4 of the RSS User's Guide, part number
68P81085E35). Follow the instructions for setting up
the test equipment and initiating a BER report using
the RSS.
Step 2. If the BER reading is above 5%, suspect the
following:
Faulty Station Control Module (2.1 MHz
reference)
Faulty Receiver Module
Faulty antenna-to-receiver preselector RF cable
Faulty top panel-to-preselector RF cable
Faulty R2670-to-station RF cable
Step 3. If you are injecting RF directly into the top panel
receiver port, change the R2670 injection signal level
to:
VHF: 0.25 µV (-119 dBm)
UHF: 0.35 µV (-116 dBm)
If you are injecting RF through a duplexer, change the
R2670 injection signal level to:
September 27, 2000