Figure 4. Pdr 3500 Station Troubleshooting Overview (Procedure 2: Reported Or Suspected Problem) - Motorola PDR 3500 Basic Service Manual

Portable repeater
Hide thumbs Also See for PDR 3500:
Table of Contents

Advertisement

A
CHECK CODE PLUG PROGRAMMING
(RSS USER'S GUIDE – 68P81085E35)
• USING RSS, READ THE STATION CODE PLUG
AND VERIFY THAT PROGRAMMING IS
CORRECT (COMPARE TO CODE PLUG FILE ON
PC FOR PARTICULAR STATION)
CODE
PLUG
PROGRAMMING
CORRECT?
INTERPRET STATUS REPORT
(RSS USER'S GUIDE–68P81085E35)
• USING RSS, ACCESS THE STATUS REPORT
SCREEN AND LOOK AT HISTORY OF ALARMS
AND TIME STAMPS
MODULE
SUSPECTED
OF BEING
FAULTY?
RUN TRANSMITTER AND RECEIVER TESTS:
• PERFORM VERIFYING TRANSMITTER CIRCUITRY
TESTS (Page 10) TO ISOLATE PROBLEM TO
TRANSMITER CIRCUITRY
• PERFORM VERIFYING RECEIVER CIRCUITRY TESTS
(Page 14) TO ISOLATE PROBLEM TO RECEIVER
CIRCUITRY
REPLACE FAULTY MODULE AS
DESCRIBED IN MODULE RELACEMENT
PROCEDURES BEGINNING ON page 25
Figure 4 PDR 3500 Station Troubleshooting Overview (Procedure 2: Reported or Suspected Problem) (Continued)
68P81093C75-O
• RE-PROGRAM STATION CODE PLUG BY DOWNLOADING
CUSTOMER DATA FROM CODE PLUG FILE FOR
NO
PARTICULAR STATION (RSS GUIDE – 68P81085E35)
• IF PROBLEM STILL EXISTS, PROCEED TO INTERPRET
STATUS REPORT
YES
GO TO MODULE REPLACEMENT
YES
PROCEDURES ON page 25
NO
September 27, 2000
PROCEDURE 2
(CONTINUED)
9-5