Overview Of Main Functions - andrews SUPAflo EVO SF60 EVO Installation And Service Manual

Table of Contents

Advertisement

Operating instructions

Overview of main functions

Button
Set room temperature
Set room temperature for
zone 1 or zone 2
Switch on /off DHW
operation
Change heating operation
mode
Auto
i
C
F
Controller Stop mode
Info display
Action
Procedure
Zone 1 and zone 2
Actuate wheel left/right
Turn wheel
Confirm with OK button
or wait 5 sec.
or press
Zone 2 independent from
zone 1
Actuate wheel left/right
Confirm with OK button
Actuate wheel left/right
Confirm with OK button
or wait 5 sec.
or press
Press button
Factory setting
Press button 1x
Press button 1x again
Press button 1x again
Press button > 3 sec.
Press button > 3 sec. again
Press button 1x
Press button 1x again
Press button 1x again
.....
= confirmation
= cancel,
return to main menu
Display / Function
Comfort setpoint with blinking temperature
Blinking temperature in 0,5 °C steps from 10 to 30 °C
Comfort setpoint saved
Comfort setpoint cancelled
- after 3 sec. Main menu appears
Choose heating zone
Heating zone is chosen
Blinking temperature in 0,5 °C steps from 10 to 30 °C
Comfort setpoint saved
Comfort setpoint cancelled
- after 3 sec. Main menu appears
DHW mode on / off
(see indication below DHW symbol)
- On: DHW mode by time programm
- Off: no DHW operation
- Safety functions activated
Automatic mode on, with:
- Heating by time programm
- Temperature setpoint by heating programm
- Safety functions activated
- Summer/Winter automatic switching activated
- ECO-functions activated
(see indication below operation symbol)
Continuous COMFORT heating on, with:
- Heating without time programm by comfort setpoint
- Safety functions activated
Continuous REDUCED heating on, with:
- Heating without time programm by reduced setpoint
- Safety functions activated
- Summer/Winter automatic switching activated
- ECO-functions activated
Safety mode on, with:
- Heating off
- Temperature by frost protection
- Safety functions activated
304: Controller Stop mode
after 3 sec. Main menu appears
INFO Segment displayed
- room temperature
- Status Boiler
- room temperature minimum
- Status DHW
- room temperature maximum -
- Status zone 1
outside temperature
- Status zone 2
- outside temp. minimum
- Time / Date
- outside temp. maximum
- Error indication
- DHW temperature 1
- Maintenance indication
- Boiler temperature
- Flow temperature
(Info display depends on configuration)
Back to main menu;
INFO Segment disappears
35