I. Access to Control Module
The following steps demonstrate how to access the control module after the unit has been installed: NOTE: Shut
down the unit and allow to cool off.
1.Remove the barrier screen on the indoor side by lifting up and out. Set aside.
2. Remove the glass door assembly by rotating the two panels toward the glass, unlatch the three latches at the top of the
firebox by pulling toward you. LIft up and release. Lift the glass up and out of the bottom door track and set aside.
3. Remove the logs and set aside.
4. Remove the right hand side brick by removing the retaining bracket, tilt the brick into the unit and pull out. Set aside.
5. Remove the access panel to access the control module by unfastening the six screws. See Figure 3.5.
Standard Wall Switch or Factory-Installed ON/OFF Switch:
Figure 3.5
J. Detailed Component Operating Instructions - IntelliFire™ Touch
IFT-ECM Detailed Operating Instruction
1. The Electronic Control Module (IFT-ECM) has a
three-position ON/OFF/REMOTE selector switch
that must be set for proper operation. See Figure 12.
When changing switch positions,it is important to
pause in each position for 1-2 seconds.
OFF Position:
The appliance will not respond to any commands
from a wired wall switch, IFT-RC150 or IFT-RC400
remote controls. The unit should be in the OFF
position during installation, service, backup battery
installation, fuel conversion and to reset the IFT-
ECM in the event the system goes into a LOCK-
OUT mode as the result of a system error. When
switched to the OFF position while the appliance is
operating, the system will shut down.
ON Position:
The appliance will ignite and run continuously at
the HI flame setting. No adjustment in flame height
is possible.
14
Outdoor Lifestyles • ODFORTG-36 Owner Manual • 4602-900 Rev. A • 12/16
B
The IFT-ECM has a safety feature that will
automatically shut down the fireplace after
B (2 : 15)
9 hours of continuous operation in the ON
position.
Remote Position:
The remote position allows operation of the
appliance from a wired wall switch, IFT-RC400 or
IFT-RC150 remote controls. The IFT-ECM switch
must be in this position to pair the IFT-ECM with the
IFT-ACM (if installed), and/or IFT-RC400 and IFT-
RC150 remote controls. See the IFT-RC400 or IFT-
RC150 installation manual for detailed instructions
on pairing the IFT-ECM with the remote controls.
After successfully pairing a IFT-RC400, all installed
accessories can be controlled by the IFT-RC400
(see IFT-RC400 user manual). The RC150 allows
the user to turn ON/OFF the flame in the appliance
and activate the Cold Climate mode if desired. The
IFT-ECM has a safety feature that will automatically
shut down the fireplace after 9 hours of continuous
operation without receiving a command from the
IFT-RC400 or IFT-RC150.