LSC22 Loudspeaker Controller
ASM-LSC22 Installation and Operation Manual
Recording for Messages 1 and 2 is accomplished by setting the rotary selector to the desired message
number and setting the PLAY/REC switch to REC while the desired audio is present. Recording ends when
the PLAY/REC switch is set to the center (off) position.
To play either Message 1 or 2 a single time, set the rotary selector to the desired message number, set the
PLAY/REC switch to the center (off) position, then momentarily activate the PLAY ONCE discrete input.
To play either Message 1 or 2 continuously, set the rotary selector to the desired message number and set
the PLAY/REC switch to PLAY. To end continuous playback, or after the message has played the desired
number of times, set the PLAY/REC switch to the center (off) position.
CAUTION:
When setting the PLAY/REC switch from PLAY to the center position (off),
ensure to not go past the switch center position to the REC position.
This will result in the selected message 1 or 2 being erased.
PLAY
PLAY to off:
Off
REC
Pull out, down
to middle
3.3.1.2
Message 3
Message 3 is stored in other dedicated non-volatile memory in the LSC22 and is up to a 120 seconds in
length. This message can only be recorded with the unit powered off. The source input is from the AUX
connector (USB input) using the supplied USB Type A to 3.5mm 4 conductor cable and the LSC-APS
software loaded with a digital wav file. Message 3 is supplied from factory with an LSC22 product
description.
To play Message 3, set the rotary selector to position 3, the SIREN KEY input must be inactive and the
WAIL/YELP switch set to OFF, then set PLAY/REC switch to PLAY. Message 3 will only play continuously.
To end continuous playback, set the PLAY/REC switch to the center (off) position.
Message 3 is not capable of being played a single time with the PLAY ONCE discrete input.
The RADIO input is not available for recording.
The LSC-APS software is available for free download from the AEM website www.aem-corp.com.