AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Content Part 1. General information ............3 Part 2. Indoor unit ................6 Part 3 Universal outdoor unit ............83 Part 4 Trouble shooting ............... 116 Part 5 Controller ................146 Part 6. Sensor resistance table ..........155...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Part 1. General information 1.Nomenclature ..................4 2.Unit appearance ................5...
Page 4
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 1.Nomenclature...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Part 2. Indoor unit Four-way cassette................. 7 Ceiling & floor type ................35 Middle static pressure duct type ............61...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 2.Specfication Indoor Unit ALCA-H12/4R1AA ALCA-H18/4R1AA Model Panel MB13 MB13 Outdoor Unit AL-H12/4R1D(U) AL-H18/4R1D(U) Indoor Unit ALCa-H12A4/R1C7-B7 ALCa-H18A4/R1C7-B7 Factory Model Panel MB13 MB13 Outdoor Unit AL-H12A4/R1(T)-B7 AL-H18A4/R1(T)-B7 Indoor Unit 16106022000055 16106022000054 Code Panel 16108004000004...
Page 10
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF (W*H*D) Packing Dimension 700×700×330 700×700×330 (W*H*D) Net Weight 17.5 Gross Weight 21.5 Net Dimension 650×650×55 650×650×55 (W*H*D) Packing Dimension 700×700×330 700×700×330 Panel (W*H*D) Net weight Gross weight Liquid Side 6.35 6.35 Gas Side 12.7...
Page 11
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Indoor Unit ALCA-H24/4R1AA ALCA-H36/5R1AA Model Panel MB12 MB12 Outdoor Unit AL-H24/4R1D(U) AL-H36/5R1D(U) Indoor Unit ALCa-H24B4/R1EB-B7 ALCa-H36A5/R1EB-B7 Factory Model Panel MB12 MB12 Outdoor Unit AL-H24A4/R1(T)-B7 AL-H36A5/R1(T)-B7 Indoor Unit 16106022000053 16106022000056 Code Panel 16108002000007 16108002000007...
Page 12
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF (W*H*D) Packing Dimension 910×910×310 910×910×310 (W*H*D) Net Weight Gross Weight 27.5 27.5 Net Dimension 950×950×55 950×950×55 (W*H*D) Packing Dimension Panel 1000x1000x100 1000x1000x100 (W*H*D) Net weight Gross weight Liquid Side 9.52 9.52 Gas Side 15.88...
Page 13
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Indoor Unit ALCA-H48/5R1AA ALCA-H60/5R1AA Model Panel MB12 MB12 Outdoor Unit AL-H48/5R1D(U) AL-H60/5R1D(U) Indoor Unit ALCa-H48A5/R1EB-B7 ALCa-H60A5/R1EB-B7 Factory Model Panel MB12 MB12 Outdoor Unit AL-H48A5/R1(T)-B7 AL-H60A5/R1(T)-B7 Indoor Unit 16106022000057 16106022000058 Code Panel 16108002000007 16108002000007...
Page 14
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Packing Dimension 910×910×350 910×910×350 (W*H*D) Net Weight 26.5 26.5 Gross Weight 30.5 30.5 Net Dimension 950×950×55 950×950×55 (W*H*D) Packing Dimension 1000x1000x100 1000x1000x100 Panel (W*H*D) Net weight Gross weight Liquid Side 9.52 9.52 Gas Side 19.05...
Page 15
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Indoor ALCA-H36/4R1E Model Panel MB12 Outdoor AL-H36/4R1(U) Indoor ALCa-H36A4/R1-EA Factory Model Panel MB12 Outdoor AL-H36A4/R1(T) Indoor 16106021000005 Code Panel 16108002000007 Outdoor 16107022000001 Power Supply V~,Hz,Ph 220~240,50,1 Btu/h 36000 Cooling 10.60 Capacity Btu/h 40000 Heating 11.70...
Page 16
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF (W*H*D) Packing Dimension 910×910×310 (W*H*D) Net Weight Gross Weight 27.5 Net Dimension 950×950×55 (W*H*D) Packing Dimension 1000x1000x100 Panel (W*H*D) Net weight Gross weight Liquid Side 9.52 Gas Side 15.88 Max. Refrigerant Pipe Refrigerant Pipe Length Max.
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 3.CapacityAmendment 3.1 Amendment coefficient of cooling capacity under different indoor/outdoor temperature Indoor temperature°C Outdoor temperature°C(DB) 0.98 0.94 0.89 0.85 0.82 0.79 0.74 0.71 1.05 0.95 0.90 0.87 0.82 0.77 0.72 1.05 0.95 0.91 0.87...
Page 18
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 3.2 Amendment coefficients of heating and cooling capacity under different height drop Different Cooling Capacity modified coefficients at different height: Note: H = Height of Outdoor Unit - Height of Indoor Unit Different Heating Capacity modified coefficients at different height: Note: H = Height of Outdoor Unit -...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 5.Electrical wiring and connection ALCA-H12/4R1AA, ALCA-H18/4R1AA...
Page 21
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCA-H24/4R1AA ALCA-H36/4R1E ,ALCA-H36/5R1AA ,ALCA-H48/5R1AA,ALCA-H60/5R1AA...
Page 22
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Electrical connection ALCA-H12/4R1AA ALCA-H18/4R1AA ALCA-H24/4R1AA,...
Page 23
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCA-H36/4R1E ALCA-H36/5R1AA,ALCA-H48/5R1AA,ALCA-H60/5R1AA...
Page 24
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Introduction of Control Board QRDL-3F(2S)-SYE1 (indoor unit) (match with the outdoor unit which the Power supply is 220V-240V, 1PH) Introduction of control board QRD-SN3F(EX)-SYE1 sockets (Indoor unit) (match with the outdoor unit which the Power supply is 380V-415V, 3PH)
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 6.Installation 6.1 Preparation before installation 1. Please buy following spare parts from your local market before installation Hung bolts M12, 4 pcs Drainage pipe PVC Copper pipe Adhesive belt (big size) 5 pcs, (small size) 5 pcs ...
Page 26
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 6.2 Installation diagram 6.3 Installation precaution ◇ Hanging location should be able to support the unit’s weight, there should be no increasement in noise and vibration. If the hanging location needs reinforcement, it should be reinforced before installation;...
Page 27
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 6.4 The distance between indoor unit and obstacle 6.5 Indoor unit suspension ◇ Select the suspension foundation: ◇ The suspension foundation is a structure of either wooden frame or reinforced concrete. It must be firm and reliable to bear at least 4 times weight of itself and capable of bearing vibration for long periods.
Page 28
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF This is as shown in the drawing as follows: ◇ Adjust the relative position of the suspension hook on the suspension bolt so that the unit can be in level position in all directions. Check with a level gauge after installation to ensure that the indoor unit is horizontal, otherwise it will cause water leakage, air leakage etc.
Page 29
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Less than 300mm Less than 600mm (Unit: mm) ◇ When draining multiple units into a common drain line, this common drain should be installed about 100mm below each units drain outlet, as shown in the drawing.
Page 30
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ◇ Fresh air ventilation: In the corner of the unit there is a circular fresh air connection hole, if users want this feature, please cut down the circular metal sheet and connect it to the duct. Fresh air hole is connected to the return air inlet of the indoor unit, when operation, the fresh air can be introduced from outside due to the negative pressure.
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 7.Explode view ALCA-H12/4R1AA, ALCA-H18/4R1AA ALCA-H12/4R1AA,ALCA-H18/4R1AA Materiel No. Chinese name Part Name Quantity 面板 MB13(英文) Panel MB13 回风格栅组件 Return-air grille assembly 空气过滤网 Air filter net 导风叶片 guide wind vane 步进电机 Step motor 显示灯板 Display board 面板围框组件...
Page 32
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 电控盒总成 Electric assembly 电容 capacitance 控制板 PCB board 变压器 Transformer 端子板 7 位 Terminal board 传感器 0.5m Sensor 0.5m 传感器 0.9m Sensor 0.9m 橡胶塞 Rubber plug 接水盘组件 Water pan 蒸发器总成 Evaporator assembly 蒸发器组件...
Page 33
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCA-H24/4R1AA, ALCA-H36/4R1E ,ALCA-H36A5/R1AA, ALCA-H48A5/R1AA,ALCA-H60A5/R1AA...
Page 34
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCA-H24/4R1AA, ALCA-H36/4R1E ,ALCA-H36/5R1AA, ALCA-H48/5R1AA,ALCA-H60/5R1AA Materiel No. Chinese name Part Name Quantity 钣金套件 Sheet metal Assembly 围板 A Cabinet A 围板 B Cabinet B 围板 C Cabinet C 底盘组件 Chassis assembly 挂钩 hook 压线扣...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 2.Specfication Indoor Unit ALCF-H18/4R1C ALCF-H24/4R1C Model Outdoor Unit AL-H18/4R1D(U) AL-H24/4R1D(U) Indoor Unit ALCe-H18A4/R1C5-B7 ALCe-H24B4/R1C5-B7 Factory Model Outdoor Unit AL-H18A4/R1(T)-B7 AL-H24A4/R1(T)-B7 Indoor Unit 16109022000011 16109022000007 Factory Model Outdoor Unit 16107022000019 16107022000018 Power Supply V~,Hz,Ph...
Page 38
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Net Weight Gross Weight Liquid Side 6.35 9.52 Gas Side 12.7 15.88 Refrigerant Pipe Max. Refrigerant Pipe Length Max. Level Difference Setting Temperature Range °C 16~32 16~32 Cooling °C -15~49 -15~49 Ambient Temperature Range Heating °C...
Page 39
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Indoor Unit ALCF-H36/4R1 ALCF-H36/5R1C Model Outdoor Unit AL-H36/4R1(U) AL-H36/5R1D(U) Indoor Unit ALCe-H36A4/R1-C5 ALCe-H36A5/R1C5-B7 Factory Model Outdoor Unit AL-H36A4/R1(T) AL-H36A5/R1(T)-B7 Indoor Unit 16209005000008 16109022000008 Factory Model Outdoor Unit 16107022000001 16107022000020 Power Supply V~,Hz,Ph 220~240,50,1...
Page 40
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Net Weight Gross Weight Liquid Side 9.52 9.52 Gas Side 15.88 15.88 Refrigerant Pipe Max. Refrigerant Pipe Length Max. Level Difference Setting Temperature Range °C 16~32 16~32 Cooling °C -15~49 -15~49 Ambient Temperature Range Heating °C...
Page 41
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Indoor Unit ALCF-H48/5R1C ALCF-H60/5R1C Model Outdoor Unit AL-H48/5R1D(U) AL-H60/5R1D(U) Indoor Unit ALCe-H48A5/R1C5-B7 ALCe-H60A5/R1C5-B7 Factory Model Outdoor Unit AL-H48A5/R1(T)-B7 AL-H60A5/R1(T)-B7 Indoor Unit 16109022000009 16109022000010 Factory Model Outdoor Unit 16107022000022 16107022000023 Power Supply V~,Hz,Ph 380~415,50,3...
Page 42
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF (W*H*D) Net Weight Gross Weight Liquid Side 9.52 9.52 Gas Side 19.05 19.05 Refrigerant Pipe Max. Refrigerant Pipe Length Max. Level Difference Setting Temperature Range °C 16~32 16~32 Cooling °C -15~49 -15~49 Ambient...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 3.Capacity amendment 3.1 Amendment coefficient of cooling capacity under different indoor/outdoor temperature Indoor temperature°C Outdoor temperature°C(DB) 0.98 0.94 0.89 0.85 0.82 0.79 0.74 0.71 1.05 0.95 0.90 0.87 0.82 0.77 0.72 1.05 0.95 0.91...
Page 44
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 3.3 Amendment coefficients of heating and cooling capacity under different height drop Different Cooling Capacity modified coefficients at different height: Note: H = Height of Outdoor Unit - Height of Indoor Unit Different Heating Capacity modified coefficients at different height:...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 5.Electrical wiring and connection ALCF-H18/4R1C ALCF-H24/4R1C...
Page 47
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCF-H36/4R1 ,ALCF-H36/5R1C, ALCF-H48/5R1C, ALCF-H60/5R1C...
Page 48
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Electrical connection ALCF-H18/4R1C ALCF-H24/4R1C...
Page 49
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCF-H36/4R1 ALCF-H36/5R1C, ALCF-H48/5R1C, ALCF-H60/5R1C...
Page 50
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF Introduction of Control Board QRDL-3F(2S)-SYE1 (indoor unit) (match with the outdoor unit which the Power supply is 220V-240V, 1PH) Introduction of control board QRD-SN3F(EX)-SYE1 sockets (Indoor unit) (match with the outdoor unit which the Power supply is 380V-415V, 3PH)
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 6.Installation 6.1 Preparation and equipments before installation 1. Please buy following spare parts from your local market before installation Hung bolts M12, 4 pcs Drainage pipe PVC Copper pipe Adhesive belt (big size) 5 pcs, (small size) 5 pcs ...
Page 52
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 6.3 Indoor unit suspension ◇ Select the suspension foundation ◇ The suspension foundation is a structure of either wooden frame or reinforced concrete. It must be firm and reliable to bear at least 4 times weight of itself and capable of bearing vibration for long periods;...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 7.Explode view ALCF-H18/4R1C Parts No. Chinese name Part Name Quantity ALCe-H18A4/C5 顶盖板 The top covers 导风门 ALCe-H18A4/C5 Sway a breeze leaf Air guide louver ALCe-H18A4/C5 导风架组件 assembly ALCe-H18A4/C5 顶泡沫 The top foam ALCe-H18A4/C5 面板...
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCe-H24B4/C5 左挂架 Left suspend plate Chassis welding ALCe-H18A4/C5 背板 assembly 风轮 φ145×190×φ12 ALCe-H18A4/C5 电机固定板 Volute fixing board 直流电机 FP40A-ZL(12 轴径) motor The electronic DR-120N/DC5-A 电控盒盖 control box cover CJ 控制板 PCB board DCZ-OXNX-SN1T1(18-60)K-SYE CJ 控制板...
Page 55
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCF-H24/4R1C ALCF-H24/4R1C Parts No. Chinese name Part Name Quantity ALCe-H24B4/C5 顶盖板 The top covers ALCe-H24B4/C5 导风架组件 Air guide louver assembly ALCe-H24B4/C5 导风架 Air guide louver 导风门 ALCe-H24B4/C5 Sway a breeze leaf ALCe-H24B4/C5 面板...
Page 56
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF 直流电机 FP90A-ZL(长短轴) Moter ALCe-H24B4/C5 左挂架 Left suspend plate ALCe-H24B4/C5 左侧板组件 Left side panel assembly ALCe-H24A4/R1DCC5-B6 背板 Chassis welding assembly 组件 联轴器 φ15 Motor coupling 加长轴 φ15×565 Motor lengthen axes ALCe-H24B4/C5 右侧板组件 Right side panel assembly ALCe-H24B4/C5 右挂架...
Page 57
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCF-H36/4R1,ALCF-H36/5R1C ALCF-H36/4R1,ALCF-H36/5R1C Parts No. Chinese name Part Name Quantity ALCe-H24B4/C5 顶盖板 The top covers ALCe-H24B4/C5 导风架组件 Air guide louver assembly ALCe-H24B4/C5 导风架 Air guide louver 导风门 ALCe-H24B4/C5 Sway a breeze leaf ALCe-H24B4/C5 面板...
Page 58
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCe-H24B4/C5 左侧板组件 Left side panel assembly ALCe-H24A4/R1DCC5-B6 背板 Chassis welding assembly 组件 联轴器 φ15 Motor coupling 加长轴 φ15×565 Motor lengthen axes ALCe-H24B4/C5 右侧板组件 Right side panel assembly ALCe-H24B4/C5 右挂架 Right suspend plate ALCe-H24B4/C5 右盖板...
Page 59
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF ALCF-H48/5R1C, ALCF-H60/5R1C ALCF-H48/5R1C, ALCF-H60/5R1C Parts No. Chinese name Part Name Quantity 导风门 ALCe-H42A5/C5 Sway a breeze leaf ALCe-H42A5/C5 导风架组件 Air guide louver assembly ALCe-H42A5/C5 导风架 Air guide louver ALCe-H42A5/C5 面板 Panel ALCe-H42A5/C5 顶盖板...
Page 60
AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF DR-140N/DC5-A 背板组件 Chassis welding assembly CJ 控制板 14.1 DCZ-OXNX-SN1T1(18-60)K- PCB board CJ 控制板 14.2 DCZ-OXNX-SNPOWER-C-S PCB board The electronic control box DR-120N/DC5-A 电控盒盖 cover ALCe-H42A5/C5 集水盘组件 Draining tray ALCe-H42A5/C5 电机固定板 Volute fixing board 橡胶轴承...
AUX-Light CAC 50Hz R410A Universal outdoor unit 2.Specfication Indoor Unit ALMD-H18/4R1D ALMD-H24/4R1D ALMD-H36/4R1 Model Outdoor Unit AL-H18/4R1D(U) AL-H24/4R1D(U) AL-H36/4R1(U) ALHi-H18A4/R1S ALHi-H24B4/R1S3- ALHi-H36A4/R1-S Indoor Unit 3-B7 Factory Model AL-H18A4/R1(T)- Outdoor Unit AL-H24A4/R1(T)-B7 AL-H36A4/R1(T) Indoor Unit 16113022000047 16113022000043 16113022000025 Code Outdoor Unit...
Page 64
AUX-Light CAC 50Hz R410A Universal outdoor unit Net Weight Gross Weight Liquid Side 6.35 9.52 9.52 Gas Side 12.7 15.88 15.88 Refrigerant Max. Refrigerant Pipe Pipe Length Max. Level Difference Setting Temperature Range °C 16~32 16~32 16~32 Ambient Cooling Temperature Range Heating °C...
Page 65
AUX-Light CAC 50Hz R410A Universal outdoor unit Indoor Unit ALMD-H36/5R1D ALMD-H48/5R1D ALMD-H60/5R1D Model Outdoor Unit AL-H36/5R1D(U) AL-H48/5R1D(U) AL-H60/5R1D(U) ALHi-H36A5/R1S3- ALHi-H48A5/R1S ALHi-H60A5/R1S Indoor Unit 3-B7 3-B7 Factory Model AL-H48A5/R1(T)- AL-H60A5/R1(T)- Outdoor Unit AL-H36A5/R1(T)-B7 Indoor Unit 16113022000044 16113022000045 16113022000046 Code Outdoor Unit...
Page 66
AUX-Light CAC 50Hz R410A Universal outdoor unit Gross Weight Liquid Side 9.52 9.52 9.52 Gas Side 15.88 19.05 19.05 Refrigerant Max. Refrigerant Pipe Pipe Length Max. Level Difference Setting Temperature Range °C 16~32 16~32 16~32 Ambient Temperature Cooling °C -15~49...
AUX-Light CAC 50Hz R410A Universal outdoor unit 3.Capacity amendment 3.1 Amendment coefficient of cooling capacity under different indoor/outdoor DB and WB Indoor temperature°C Outdoor air inlet DB°C 0.98 0.94 0.89 0.85 0.82 0.79 0.74 0.71 1.05 0.95 0.90 0.87 0.82 0.77...
Page 68
AUX-Light CAC 50Hz R410A Universal outdoor unit 3.3 Amendment coefficients of heating and cooling capacity under different height drop Different Cooling Capacity modified coefficients at different height: Note: H = Height of Outdoor Unit - Height of Indoor Unit Different Heating Capacity modified coefficients at different height:...
Page 74
AUX-Light CAC 50Hz R410A Universal outdoor unit Introduction of Control Board QRDL-3F(2S)-SYE1 (indoor unit) (match with the outdoor unit which the Power supply is 220V-240V, 1PH) Introduction of control board QRD-SN3F(EX)-SYE1 sockets (Indoor unit) (match with the outdoor unit which the Power supply is 380V-415V, 3PH)
AUX-Light CAC 50Hz R410A Universal outdoor unit 7.Installation 7.1 Preparation and equipments before installation 1. Please buy following spare parts from your local market before installation Hung bolts M12, 4 pcs Drainage pipe PVC Copper pipe Adhesive belt (big size) 5 pcs, (small size) 5 pcs ...
Page 78
AUX-Light CAC 50Hz R410A Universal outdoor unit the room; ◇ In order to facilitate maintenance and repair, there should be certain distance between indoor unit and obstacles; ◇ Refrigerant R22 is used for this unit, which is non-flammable and non-toxic gas. As the proportion of refrigerant is bigger than air, so if it leaks the gas will be filled on the ground.
AUX-Light CAC 50Hz R410A Universal outdoor unit 7.6 Drainage pipe ◇ Drainage pipes must be wrapped with heat insulation materials, otherwise it will cause frost or droplets, see picture as follows: Heat insulation material: rubber insulation pipe with the thickness of more than 8mm ◇...
Page 82
AUX-Light CAC 50Hz R410A Universal outdoor unit 电控盒盖 Electronics Box cover 出风法兰 A Air outlet flange A 出风法兰 B Air outlet flange B 排水管保护板 B Drain pipe bracket B 排水管保护板 A Drain pipe bracket A 凝水盘组件 Drain pan assembly 底板...
Page 87
AUX-Light CAC 50Hz R410A Trouble shooting Design Pressure Liquid Side 9.52 9.52 Gas Side 15.88 15.88 Refrigerant Piping Max. Length Max. Height Setting Temperature Range °C 16~32 16~32 Operation Cooling °C -15~49 -15~49 Temperature Range Heating °C -15~24 -15~24 Application Area...
Page 88
AUX-Light CAC 50Hz R410A Trouble shooting Motor code Brand Sinjun/Welling Sinjun/Welling Output Power x Fan Quantity 60×2 60×2 Capacitor 3.5×2 3.5×2 Speed r/min Number Of Rows Tube Pitch(a)x Row Pitch(b) 22×19.05 22×19.05 Fin Pitch Coil Fin Material Hydrophilic aluminum fin Hydrophilic aluminum fin φ7,...
AUX-Light CAC 50Hz R410A Trouble shooting 2. Capacity Amendment 2.1 Amendment coefficient of cooling capacity under different indoor/outdoor DB and WB temperature Indoor air inlet Outdoor air inlet DB temperature°C temperature°C 0.98 0.94 0.89 0.85 0.82 0.79 0.74 0.71 1.05 0.95...
Page 90
AUX-Light CAC 50Hz R410A Trouble shooting 2.4 Amendment coefficients of heating and cooling capacity under different height drop Different Cooling Capacity modified coefficients at different height: Note: H = Height of Outdoor Unit - Height of Indoor Unit 2.5 Different Heating Capacity modified coefficients at different height:...
AUX-Light CAC 50Hz R410A Trouble shooting 4. System principle diagram Cooling circle: the Compressor inhales the low-temperature and low-pressure refrigerant vapor from the evaporator, and vapor be turned into high-temperature and high-pressure gas then enters into condenser, the high-temperature and high-pressure refrigerant gas and outdoor air make heat exchange in the...
AUX-Light CAC 50Hz R410A Trouble shooting 6. Explore View AL-H12/4R1D(U) AL-H18/4R1D(U) AL-H12/4R1D(U), AL-H18/4R1D(U) Chinese Name Part Name Quantity Parts No. 顶盖板 Top Cover 左侧板 Left side panel 前面板 Front Panel 网罩 Grille 风叶 电机 Fan Motor 电机支架 Motor Bracket 电气总成...
Page 100
AUX-Light CAC 50Hz R410A Trouble shooting AL-H24/4R1D(U) AL-H24/4R1D(U) Chinese name Parts name Quantity Parts No. 顶盖板 Top cover 左侧板 Left-hand board 冷凝器总成 Condenser assembly 轴流风叶 Axial flow fan 大面板 Big panel 网罩 Grille 室外电机 ODU fan motor 电机架 Motor support 隔风立板...
Page 101
AUX-Light CAC 50Hz R410A Trouble shooting AL-H36/4R1(U),AL-H36/5R1D(U) AL-H36/4R1(U),AL-H36/5R1D(U) Parts No. Chinese Name Part Name Quantity 顶盖板 Top cover board 冷凝器总成 condenser assembly 左侧板 Left-hand board 电机架组件 Motor bracket assembly 室外风扇电机 Outdoor Motor 轴流风叶 Axial-flow wind leaves 面板 Big panel 面板网罩...
AUX-Light CAC 50Hz R410A Trouble shooting AL-H48/5R1D(U), AL-H60/5R1D(U) Parts No. Chinese name Parts name Quantity 立柱 Stand column 顶盖板 Top cover 冷凝器总成 Condenser assembly 电机架 Motor support 大面板 Big panel 网罩 Grille 轴流风叶 Axial flow fan 小挖手 Handle care 室外电机...
AUX-Light CAC 50Hz R410A Trouble shooting 7. Installation 7.1 Preparation and equipments before installation 1. Please buy following spare parts from your local market before installation Hung bolts M12, 4 pcs Drainage pipe PVC Copper pipe ...
Page 105
AUX-Light CAC 50Hz R410A Trouble shooting Maintenance and ventilation space ◇The site shall be easy for ventilation then the outdoor unit can inhale and discharge air easily. What’s more please reserve enough space for maintenance. Note: Require A>300mm; B>1500mm; C>300mm; D>500mm Outdoor unit installation ◇Use size M10 bolt and nut to fasten the outdoor unit tightly on the bracket, keep it in the horizontal level.
Page 106
AUX-Light CAC 50Hz R410A Trouble shooting Piping connection ◇Using expanding machine to expand accessories, the size of horn shown in the above figure: ◇Paint a thin layer of frozen oil at both inside and outside part of the expanding. ◇Make the expanding right to the screw thread shape connection of the indoor unit, using hands to tighten the nut then using a wrench to tighten the nut again, the tighten torque as follows figure.
Page 107
AUX-Light CAC 50Hz R410A Trouble shooting Max. Bend Qty Extra R410a per meter when the 0.03 0.03 0.05 0.05 0.07 pipe length is more than 5 meter (kg) Caution: 1.The standard Pipe length is 5m, if the pipe length is less than this then no additional charging is necessary.
Page 108
AUX-Light CAC 50Hz R410A Trouble shooting Heat insulation package of piping ◇ Use heat insulation material with good insulation performanCF to wrap the pipe. Incorrect Correct Gas pipe and liquid pipe should Insulate the gas pipe Insulate the gas pipe and...
Page 109
AUX-Light CAC 50Hz R410A Trouble shooting Additional refrigerant charge When pipe length exceeds 5m, please add refrigerant according to the table below: Piping size) Connection Additional refrigerant piping Gas pipe Liquid pipe charge amount (kg/m) φ9.52×0.75mm φ6.35×0.75mm 0.02 Piping φ12.7×1mm φ6.35×0.75mm...
Page 110
AUX-Light CAC 50Hz R410A Trouble shooting When the vertical pipe height difference is less than 5 meters, an oil loop should be installed at the bottom of the gas (large) pipe; When the vertical pipe height difference is more than 5 meters, then for every 5 meters an oil loop must be installed at the bottom of the gas (large) pipe, and a short loop (liquid ring) should be installed at the exit of the indoor unit liquid (small) pipe;...
Page 111
AUX-Light CAC 50Hz R410A Trouble shooting 7.3. Electrical connection 7.3.1Electrical connection precaution Installation of electric items must be carried out by qualified, professional technicians. An isolated circuitry should be fixed with whole-pole disconnection devices, which is with at least 3mm gap of touch point. .
Page 112
AUX-Light CAC 50Hz R410A Trouble shooting 7.3.2 Electrical connection Wiring diagram of indoor & outdoor, refer to the section of part 1 Recommendation of power supply cord Power supply:220V-240V~,50Hz Cooling capacity Power supply Power supply Power supply Model Connection wires (Btu/h) spec.
Page 113
AUX-Light CAC 50Hz R410A Trouble shooting electrician. ◇ All of the ceiling/floor type unit is without accessorial electric heating 7.3.3 wire connection Remove electric control box cover of indoor unit, connect the wires in accordance with the electri diagram mentioned on the back of the cover. The wire ends must be tightly fixed into terminal boards without ease.
Page 114
AUX-Light CAC 50Hz R410A Trouble shooting condition ◇ Operate machine 1 hour with “cooling” mode and check if the drainage system is on proper condition ◇ Switch the mode for “heating” and check if there is warm air come from indoor, if there is abnormal noise come from indoor/outdoor units ◇...
Page 115
AUX-Light CAC 50Hz R410A Trouble shooting 7.5. Compressor freezing oil brand and standard oil charge Outdoor model Brand Compressor Model Compressor Lubricating Oil Model Oil charge (cm ASL150UV-C7LU HAF68D1 AL-H12/4R1D(U) HIGHLY HAF68D1 AL-H18/4R1D(U) HIGHLY ASL205UV-C7EQ ASH286UV-C8DU HAF68D1 AL-H24/4R1D(U) HIGHLY AL-H36/4R1 (U)
AUX-Light CAC 50Hz R410A Trouble shooting 1.Main components of air conditioner Appellation Figuration and inner configuration Instruction Rotary compressor The function of compressor: after refrigerant evaporate in evaporator, compress the low temp and low pressure refrigerant gas, make the gas become...
Page 118
AUX-Light CAC 50Hz R410A Trouble shooting Elec.box Motor Function of evaporator: Evaporator Make the low pressure refrigerant liquid (heat from capillary or expansion valve happen exchanger) heat exchange with air Evap. Tray Elec. heater Function of capillary: Capillary Utilize aperture and length change bring (throttle pressure gap., control refrigerant flow...
Page 119
AUX-Light CAC 50Hz R410A Trouble shooting Function: Stop valve To stop or release refrigerant, only on/off, can’t adjust or throttle Function: Muffler Eliminate the system noise Function: Gas and liquid Separate liquid and gas refrigerant, separator to protect the compressor...
AUX-Light CAC 50Hz R410A Trouble shooting 2.Electrical system main components Appellation Figuration and inner configuration Instruction Function: Via program to control the relay, make every components on/off according to temperature and pressure variety, so to realize automatic control Function: Fan motor Drive the fan, make the indoor and outdoor unit have heat exchange with air.
Page 121
AUX-Light CAC 50Hz R410A Trouble shooting Heat relay is normally made up of double metal sheet, when the Current setting Release link current is too large, the double button metal sheet will heat distortion and movement, and open the protection...
AUX-Light CAC 50Hz R410A Trouble shooting 3.Poor efficiency explanation During the process of using air conditioner, some phenomenon seems to be malfunction but actually not. Thus when cooling effect does not to your expectation, the following factors have to be...
AUX-Light CAC 50Hz R410A Trouble shooting 4.Failure phenomenon Phenomenon Causing explanation Mirage comes out from indoor When the cold air from AC cools the indoor air unit 1. When air conditioner stops running, there will be some noise, and this is because the refrigerant flows contrarily.
AUX-Light CAC 50Hz R410A Trouble shooting 5.Electric components malfunction inspection Component Inspection methods name Using multi-meter ohm phase, there is correct resistance value among windings (single Compressor phase compressor refers to specification, three phase compressor resistance approximately equal), resistance of winding should be infinite.
AUX-Light CAC 50Hz R410A Trouble shooting 6.Failure code display When air condition has failure, the timing lamp on light board of controller will display different code according to different failure case. 6.1 Unit failure code for unit power supply is 220-240V...
Page 126
AUX-Light CAC 50Hz R410A Trouble shooting Indoor temp. sensor Flash 1 times and go out - shutdown abnormal(TA) Indoor coil sensor Flash 3 times and go out - shutdown abnormal(TE) Outdoor coil sensor Flash 2 times and go out Flash 2 times...
AUX-Light CAC 50Hz R410A Controller 1.General information Remote controller, wired controller, display panel and receiver Remote controller、wired controller、display panel 、receiver Remote Available for all models above controller Wired Available for all models above controller Display Available for Cassette indoor unit...
Page 148
AUX-Light CAC 50Hz R410A Controller Remote controller’s operation introduction Basic condition of remote controller Name Figure Basic condition for operation 1.Power source Use 2 pcs No 7 batteries,working voltage:2.0V-5.0V; 2. Signal frequency:infrared frequency 38kHz; 3. Remote distance:max working distance is7m。...
Page 149
AUX-Light CAC 50Hz R410A Controller 2.Function Function Remote conntroller: K series POWER button:Switch the unit ON/OFF. MODE button:Select mode , push the button one time, then the operation modes will change in turn as Auto-Cooling-Dehumidify-Heating TEMP + button and TEMP - button: Temperature adjustment range: 16~32...
Page 150
AUX-Light CAC 50Hz R410A Controller Timer setting: Press the button to set TIMER ON/OFF , press the button then “ON” will flicker on the display screen. then press【+】 and 【-】 button and to adjust hour that uses 12-hour clock including “A.M.”...
Page 151
AUX-Light CAC 50Hz R410A Controller MODE button:Select mode , push the button one time, then the operation modes will change in turn as Auto-Cooling-Dehumidify-Heating TEMP + button and TEMP - button: Temperature adjustment range: 16~32 FAN button: Change the fan speed will change in turn as: Low-Medium-High-Auto SWING button: Press this button for the first time when operation, it will start the swing function.
Page 152
AUX-Light CAC 50Hz R410A Controller 3.Wired controller 3.1 Basic condition of wired controller Name Figure Basic condition for operation 1. Power source:voltage DC 12V; Wired 2. Work temperature range of PCB:(-10~+70)℃; controller 3. Work humidity range of PCB:RH20%~RH90%; 3.2 Function...
Page 153
AUX-Light CAC 50Hz R410A Controller Notes:Virtually all functions of the wired controller are the same as those of the remote controller and you should refer to the remote controller instructions. Wired controller: XK-02 ON/OFF button Switch the unit ON/OFF. Mode button:Select mode , push the button one time, then the operation modes will change in turn as below: Auto-Cooling-Dehumidify-Heating Temp +/- button: Press the button can adjust temperature.
Page 154
AUX-Light CAC 50Hz R410A Controller 3. After the setting of sleeping mode,the heating operation enables the set temperature to drop 2℃ after 1 hour and another 2℃ auto matically after 1hour. 4. The air condition runs in sleeping mode for 7hours and stops automatically.