The user manual applies to the following device types: IRS3232 The images of IRS3232 are adopted in the following descriptions. Any of the different specifications between the device types are elaborated. Before reading the manual, please confirm the device type.
The IRS Series routers are designed for easy control by the IRS Series remote control panels, the routers are a series of Matrix products developed by OSEE with high intelligent and low cost, which applied to medium and small sized broadcast system switching digital HD/SD signals.
Page 8
Overview Support power off memory, the output and the signal source will keep the relationship after power off or power restarted. Functionality The buttons of the IRS series show the reality of the current work status of each signal. It would monitor and text each channel of input signal.
Safety Chapter 2 Safety FCC Caution Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 10
Safety Warnings: Read, keep and follow all of these instructions for your safety. Heed all warnings. Device Do not beat with a hard object or scratch the device. Install in accordance with the manufacturer's instructions. Refer all servicing to qualified service personnel. Servicing will be required under all of the following conditions: ...
Page 11
Safety The socket-outlet shall be installed near the equipment and shall be easily accessible. Power Supply Cord Do not defeat the safety purpose of the polarized or grounding-type plug. Do not damage the power cord, place the heavy objects on the power ...
Unpack: When unpacking the components of router, please verify that none of the components listed in Table 3.1 are damaged or lack. If there is any missing, contact your distributors or OSEE for it. Table 3.1 Packing List Item Quantity...
Page 14
Unpack and Installation Connect a standard signal line to the corresponding signal port. All BNC connector impedance must be 75Ω. Please use the power adapter supplied to avoid unnecessary trouble. The factory default value for IP address is 192.168.1.86. 8 ...
Device Features Chapter 4 Device Features This chapter describes the features of router. The features of router are as shown as follows. 4.1 Outward Appearance Figure 4.1-1 the Front Panel of Remote Control Panel The signals controlled by the IRS series are divided as follows according to their functions: ...
Device Features 4.1.1 Front Panel Features It will introduce the information afforded by the front panel. Figure 4.1-2 the Front Panel of Router As shown in Figure 4.1-2, the information afforded is as follows: Power Indicator Used to indicate the power on or off, corresponding to the power inputs sequentially from up to down at the rear panel.
Page 17
Device Features Table 4.1-1 The Relationship of Pins and Interfaces for RS422 Pins RS422 Input RS422 Output Power Input It offers two redundant power interfaces, 12V 5A. Only use the adapter and the power cord specified by the manufacture for your safety!...
Page 18
Device Features PIN No. RS485 IN Terminal Signal RS485 OUT Terminal Signal Ethernet (RJ-45) It is used to connect with a computer to access the network control page or run the device control tool to modify the network settings, set up a network system, or update the software of the device.
Page 19
Device Features For a router, if the higher 4 bits are ON, it will restore the default IP, the default value of IP address is 192.168.1.86. When the remote control panel is cooperating with the router, the valid range of the address of remote control panel is from 1 to 254.
Device Application Chapter 5 Device Application This chapter describes the usages, operations and cautions of the IRS series devices. 5.1 Network In an application of IRS series devices, the router is usually cooperating with the remote control panel as an integrated system. The process of the construction is usually called network control.
Device Application Figure 5.1-2 A Complex System Connection principle: use the Ethernet interface to connect the router and the remote control panel. The IP address should not be repeatable in a network system. 5.2 Operations You can do the following operations to a router before operating: Step 1 Connect the input resource signals INPUT at the rear panel of the router.
Use Internet Explorer as your web browser to enter into a web control page, input the default network IP address of the device. For example, input http://192.168.1.86 in address bar, then press Enter key, the management interface of IRS3232 is shown as in Figure 6.1-1: Figure 6.1-1 Network Control Page 17 ...
Network Control You can select StatusLanguage command to change the language setting. Either the router or the remote control panel can only access the network control page of itself. The default IP address of remote control panel is 192.168.1.7. 6.2 Network Control Open the management interface as shown in Figure 6.2-1, and there are two menu tabs:...
Page 25
It is used to set up the name of the device, and it already displays the default parameter including Name and Type.Input a customized name in the field of NAME, the default value is “OSEE-Panel-0000”, you can use any characters, and the length of name can be up to16 characters.
Page 26
Network Control Classify Items Default Value Description It displays the IP address of the Gateway 192.168.1.1 gateway. It displays the IP address which is Alarm IP 192.168.1.100 used receive alarm information. It displays the communication port Alarm Port 8000 which is used to receive the alarm information.
Page 27
Network Control Detection Type Items Description Function and when it is not the current output. Select a color for a signal source whose status Abnormal abnormal and when it is not the current output. Select a color for the output Activation channel when it is the current output.
Network Control In STATUS page, check the information of router in “ROUTER” page, and check the information of remote control panel in “REMOTER” page. 6.2.2 REMOTER It will introduce REMOTER tab in this section. The REMOTER tab is used to set the signal source for the output destination connecting to the buttons of the IRS series devices.
Page 29
Network Control Step 1 Click DEST1 for selecting the target output channel, as shown in Figure 6.2-7, the DEST1 button turns green. Figure 6.2-7 Shortcut Button Settings The default signal source for DEST1 is SRC1. Step 2 Switch signal source Click SRC10 button, as shown in Figure 6.2-8, the SRC10 button turns green, thus the signal source of DEST1 is switched to SRC10.
LEVEL1 and the LEVEL2 button of the remote control panel to control these routers.Set the device settings as shown in Table 6.3-1: Table 6.3-1 The Settings Information to the Devices Type Name IP Address Level Remote Control Panel OSEE-Panel-0001 192.168.1.7 Router OSEE-Router-0000 192.168.1.86 LEVEL1 Router OSEE-Router-0001 192.168.1.87 LEVEL2 Use the network control page to set the information.
Page 31
Network Control Figure 6.3-1 The Level Settings of the Device 25 ...
<270 ps for 1.5 Gb/s HD <135 ps for 3 Gb/s HD Extinction Ratio >8 Back Reflection <-14 dB Power Consumption -10°C~+55°C Work Temperature Work Humidity 10%~90% Dimensions The description of the product dimensions of IRS3232 is shown as in the following figures: 27 ...
Page 34
Specifications Figure 7-1 Front Panel(Unit: mm) Figure 7-2 Rear Panel(Unit: mm) Figure 7-3 Side View(Unit: mm) Figure 7-4 Top View(Unit: mm) The label of IRS3232 is shown as below: 28 ...
Page 35
Specifications Figure 7-5 Label for IRS3232 in Front Panel Figure 7-6 Label for IRS3232 in Rear Panel Specifications are subject to change without notice. ------------------No Text Below------------------ 29 ...
Page 37
FOR MORE INFORMATION PLEASE VISIT: http://www.osee-dig.com/ OSEE TECHNOLOGY CO., LTD. No.22 Building, No.68 zone, Beiqing Road, Haidian District, Beijing, China Tel: (+86) 010-62434168, Fax: (+86) 010-62434169 E-mail: sales@osee-dig.com...