Daikin FTXG09HVJU Operation Manual page 33

Hide thumbs Also See for FTXG09HVJU:
Table of Contents

Advertisement

Troubleshooting
„ FAULT DIAGNOSIS BY REMOTE CONTROLLER
In the ARC447A3, the temperature display sections on the main unit indicate corresponding codes.
1.
Hold the timer cancel button down for 5 seconds, with the remote controller set toward the indoor unit.
2.
The temperature display on the remote controller changes to the error code display and
a long beep notifies this indication change.
SYSTEM
INDOOR UNIT
OUTDOOR UNIT
NOTE
• To cancel indication of error code, hold the timer cancel button down for 5 seconds.
The code display also cancels itself if the button is not pressed for 1 minute.
32
CODE
00
NORMAL
UA
INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0
REFRIGERANT SHORTAGE
U2
DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4
FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
U7
CIRCUIT BOARD TRANSMISSION FAULT
AH
STREAMER FAULT
A1
INDOOR PCB DEFECTIVENESS
A5
HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6
FAN MOTOR FAULT
C4
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C7
FRONT PANEL OPEN/CLOSE FAULT
C9
FAULTY SUCTION AIR TEMPERATURE SENSOR
EA
COOLING-HEATING SWITCHING FAULT
E1
CIRCUIT BOARD FAULT
E5
OL STARTED
E6
FAULTY COMPRESSOR START UP
E7
DC FAN MOTOR FAULT
E8
OVERCURRENT INPUT
FA
EJECTION PRESSURE FAULT
F3
HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6
HIGH PRESSURE CONTROL (IN COOLING)
H0
SENSOR FAULT
H6
OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8
CT ABNORMALITY
H9
FAULTY SUCTION AIR TEMPERATURE SENSOR
J3
FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3
ELECTRICAL PARTS HEAT FAULT
L4
HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5
OUTPUT OVERCURRENT
P4
FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
CANCEL button
It cancels the timer setting.
MEANING