POWER WAVE E500
PROBLEMS
(SYMPTOMS)
Cannot Connect.
Connection Drops while welding.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
1. Physical connection.
2. IP address information.
1. Cable Location.
CAUSE
ETHERNET
1. Verify that the correct patch cable or
2. Use Weld Manager (included on the
1. Verify Network cable is not located next
E-8
TROUBLESHOOTING
RECOMMENDED
COURSE OF ACTION
cross over cable is being used (refer to
local IT department for assistance).
• Verify the cables are fully inserted into
the bulk head connector.
POWER WAVE Utilities or available at
www.powerwavesoftware.com) to verify
the correct IP address information has
been entered.
NOTE:
• The Power Wave E500 has a default
static IP address of 192.16.8.0.2.
• Verify no duplicate the IP addresses exist
on the network.
to current carrying conductors. This
would include input power cables and
welding output cables.