Use a three-phase supply line. A 1.75 inch (45 mm) diameter access
hole for the input supply is located on the case back. Remove the
reconnect access panel located on the case back and connect L1,
L2, L3 and ground according to the Input Supply Connection Diagram
decal. (See Figure B.1)
1
4
5
1.
Input Power Cord Access Hole
• Route input power cable through this hole.
• Strain relief required. See your local and national
electrical codes for proper strain relief.
2.
Access Panel – Allows access for connecting input
power
3.
Auxiliary Power Fuse Protection
4.
Input Power Connection Terminal Block
• A ground terminal with the symbol shown
provided separate from this block for connecting the
ground lead of the line cord. See your local and national
electrical codes for proper grounding methods.
5.
OPTION – Base Mounting Kit
Input Fuse and Supply Wire Considerations
Refer to Page A-1 for recommended fuse, wire sizes and type of
the copper wires. Fuse the input circuit with the recommended
super lag fuse or delay type breakers (also called "inverse time"
or "thermal/magnetic" circuit breakers). Choose input and
grounding wire size according to local or national electrical codes.
Using input wire sizes, fuses or circuit breakers smaller than
recommended may result in "nuisance" shut-offs from welder
inrush currents, even if the machine is not being used at high
is
currents.