Philips Hudson2 200P3 Service Manual page 26

20" tft lcd colour monitor
Table of Contents

Advertisement

26
Hudson2 200P3
Go to cover page
Step 6 :
Remove 10 screws
as shown in Fig. 11.
Step 7 :
After removing metal shield,
inverter, power & scaler
board are as shown in
Fig. 12.
Step 8 :
Remove 5 screws and
disconnect the connectors,
then Scaler board can be
taken out as shown
in Fig. 13.
SCREW
Step 9 :
Disconnect CN1~CN5
on inverter board and
remove 3 screws, inverter
board can be taken out
as shown in Fig. 14.
Step 10 :
Remove 3 screws and
disconnect the connectors,
then Power board can be
taken out as shown
in Fig. 15.
Mechanical Instructions (Continued)
===>
metal shield
===>
10 SCREWs
Fig. 11 (metal shield)
inverter power
scaler
Fig. 12
Fig. 12
5 SCREWs
1705
1311
1711
1704
1703
1201
1601 1632 1633
Fig. 13
CN3
CN2
CN5
CN4
Fig. 14
SCREWs
Fig. 15
Step 11 :
Inverter,power & scaler
board are as shown in Fig. 16.
Step 12 :
Remove a screw
as shown in Fig. 16.
Step 13 :
Turn the "Panel with metal shield",
then remove the Front Bezel
(plastic clip)
as shown in Fig. 17.
Step 14 :
Remove 4 screws
as shown in Fig. 18.
1701
Step 15 :
Turn the panel again,
remove metal frame of
LCD panel as shown in
Fig. 19.
Step 16 :
Remove 2 screws
as shown in
Fig. 19.
PCB assembly ----------->
PCB assembly of
LCD panel as shown in
Fig. 20.
*************************************************************************
In warranty, it is not allowed to disassembly the LCD panel,
even the "Backlight unit" defect.
************************************************************************
scaler board ===>
SCREW
Fig. 16
Fig. 17
Front bezel ----->
Front control board
Fig. 18
Fig. 19
Fig. 20
1912 1906
metal frame
screw
LCD panel

Advertisement