Summary of Contents for Konica Minolta BIZHUB PRESS C1100

  • Page 1 2016. 6...
  • Page 2: Notations And Symbols Used In This Manual

    This guide describes product names and system configurations as follows. Product name Conventions used in this guide bizhub PRESS C1100/C1085 This machine: Indicates the entire system including options and functions. The main body: Indicates a main unit that covers printing functions.
  • Page 3: Impermissible Operating Conditions

    The Daily Maintenance Guide are intended for the following users of this machine: Operator: Person who has been trained by Konica Minolta or authorized partner to operate the system for its intended use as well as manage consumables, and perform the maintenance and troubleshooting described in user's guides.
  • Page 4: Table Of Contents

    Contents Intended use of this machine ........... i Intended use.
  • Page 5 PRESS C1100/C1085 Check setting of Color Density Control ........3-28 Color Density Manual Control .
  • Page 6: Daily Care

    DAILY CARE About daily care To reproduce stable output by this machine, be sure to clean the machine before output. )Cleaning timing Check the cleaning section every day before you activate the power of the machine. Clean the cleaning section when the cleaning section is dirty. Cleaning section Reference Duplex section...
  • Page 7: Cleaning The Duplex Section

    PRESS C1100/C1085 Cleaning the duplex section CAUTION Be sure to check the cleaning section before you activate the power of the main body. If you activate the power with closed the door of the main body, the inside of the fusing unit becomes hot. Therefore, you possibly get burned when you clean near the fusing unit.
  • Page 8 Tilt the lever [M1] counterclockwise. Hold the lever [M1], and pull out the duplex section. Deactivate the sub power switch, then deactivate the main power switch. Wipe off the dirt at the upper side of the duplex section with a hydro-wipe (non- woven fabric without fluff).
  • Page 9 PRESS C1100/C1085 Open the cover [M3]. Wipe off the dirt at the paper path of the registration unit with a hydro-wipe (non- woven fabric without fluff). Close the cover [M3]. Wipe off the dirt at the pre-fusing guide plate with a hydro-wipe (non-woven fabric without fluff).
  • Page 10 Moisten the hydro-wipe (non-woven fabric without fluff) with isopropyl alcohol, and clean the dirt of the fusing unit entrance guide. Hold the lever [M8], and open the paper path of the duplex unit. Moisten the hydro-wipe (non-woven fabric without fluff) with isopropyl alcohol, and clean the dirt of the paper path of the duplex unit.
  • Page 11: Cleaning The Centering Sensor (Paper Feeder Unit Pf-707/Pf-708)

    PRESS C1100/C1085 Cleaning the centering sensor (Paper feeder unit PF-707/PF-708) Open the front door of the paper feeder unit. Open the cover [PF4]. Clean the centering sensor with a cleaning pad. NOTICE Do not use alcohol when you clean the sensor. The surface of the sensor becomes fuzzy.
  • Page 12: Cleaning The Roller Of The Humidification Section (Relay Conveyance Unit Ru-511)

    Cleaning the roller of the humidification section (Relay conveyance unit RU-511) Open the front door of the relay conveyance unit. Hold the handle [HM1], and pull out the humidification unit. Hold the lever [HM2], and open the paper path. Moisten the cleaning pad with isopropyl alcohol, and clean the roller.
  • Page 13: Both Sides Adjustment

    PRESS C1100/C1085 BOTH SIDES ADJUSTMENT About both sides adjustment To maintain stable both sides accuracy against a change in ambient temperature or humidity, a change of this machine conditions, or a change of the both sides accuracy due to the paper type, perform the both sides adjustment at periodic intervals.
  • Page 14: Adjustment Timing

    Regular adjustment flow )Adjustment timing When you change the brand, weight, or size of the paper inside the tray NOTICE When you have not changed the paper inside the tray for more than one day, perform the adjustment before you output the job (before the adjustment flow for each job).
  • Page 15: Contents Of Both Sides Adjustment Items

    PRESS C1100/C1085 Contents of both sides adjustment items This section describes the contents of the following six adjustment items. Placing paper (Page 2-3) Front side adjustment (Page 2-6) Gap adjustment (When not using PF-708 scanner) (Page 2-11) Scan measurement adjustment (When using PF-708 Scanner)
  • Page 16 Slide the side guide plates on both sides, and press the side guide plates against the paper. Turn the bottom plate fixing knob counterclockwise to loosen it, slide it to the front, and turn it clockwise to fix the plate. Return the tray to its original position, then withdraw it again after the bottom plate of the tray goes up completely.
  • Page 17 PRESS C1100/C1085 Lower the bottom plate of the tray. Turn the bottom plate fixing knob counterclockwise to loosen it, slide it to the back, and turn it clockwise to fix the plate. The bottom plate automatically goes down. Load the remaining paper into the tray, then press the rear guide plate against the paper.
  • Page 18: Front Side Adjustment

    )Front side adjustment Press [Paper Setting] on the [MACHINE] screen. Press the tray with the target paper loaded. Press [Recall].
  • Page 19 PRESS C1100/C1085 Select the paper profile of the same paper brand (paper profile name), "Paper size", "Type of paper" and "Paper weight" as the paper that you want to adjust. Then, select [OK]. When there is no paper profile to select, select [Cancel].
  • Page 20 Press [Print Mode]. When the [PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed out. NOTICE Output about 3 sheets. Press [Exit Print Mode].
  • Page 21 PRESS C1100/C1085 Check the length of [2], [4], [6], and [8] of the charts that are output as the second and third sheet. [ 5 ] [ 1 ] Write down the measured lengths so that you do not forget them.
  • Page 22 Output the front side adjustment chart again, and check the length of [2], [4], [6], and [8] of the charts that are output as the second and third sheet. Repeat from step 11 to step 14 until the length of [2], [4], [6], and [8] are within the range of the following values.
  • Page 23: Gap Adjustment (When Not Using Pf-708 Scanner)

    PRESS C1100/C1085 )Gap adjustment (When not using PF-708 scanner) NOTICE The Gap Adjustment is a simple method to adjust only the zoom ratio and image position of the back side. To also adjust it on the front side, carry out "Front Side Adjustment"...
  • Page 24 Press [Both Sides Adj.]. Press [Print Mode]. When the [PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed out. NOTICE Output about 3 sheets. Press [Exit Print Mode]. 2-12...
  • Page 25 PRESS C1100/C1085 Measure the back side image difference at each point from [a] to [d] that is positioned at the [back] side of the second and third output charts. The scale resolution is 0.5 mm. The black line in the figure shows the back side, and the blue dashed line shows the other side (front side).
  • Page 26 Press [a] to [d] of each point, and enter the adjustment value using the keypad, [,], or [+] on the screen. When entry processing is completed, press [Adjustment Start]. The input adjustment value is reflected to the "Zoom" value and the "Image Shift" value at the [Back] screen.
  • Page 27 PRESS C1100/C1085 Press [Exit Print Mode]. Press [OK] to exit the adjustment. 2-15...
  • Page 28: Scan Measurement Adjustment (When Using Pf-708 Scanner)

    )Scan measurement adjustment (When using PF-708 Scanner) Adjust the magnification ratio and printing position of the back side with reference to the printing position of the front side. The magnification ratio and printing position of the back side are automatically adjusted by using the scanner function of this machine to measure the gap amount in printing position of the back side to the front side.
  • Page 29 PRESS C1100/C1085 Press [Both Sides Adj]. Check that [Scan Meas.] is displayed, then press [Output Background Sheet]. When the [PRINT MODE] screen is displayed, press Start on the control panel. A background sheet is printed out. If you already...
  • Page 30 Press [Exit Print Mode]. Press [1. Output Adjustment Chart]. Enter the number of adjustment charts you want to print out. however, only up to 20 adjustment charts can be scan-measured continuously. Press Start on the control panel. Adjustment charts are printed on both sides of the paper in the tray you selected in Step 2.
  • Page 31 PRESS C1100/C1085 Press [Exit Print Mode]. Press [2. Scan Adjustment Chart]. The [Scan Adjustment Chart] screen is displayed. Place an adjustment chart on the original glass. Open the ADF, then place an adjustment chart with the front side facing up (not facing the original glass), setting the top side flush with the far end of the glass.
  • Page 32 Place the background sheet on the original glass, then close the ADF. Place the black side of the background sheet facing down (facing the original glass), then set it flush with the vertical size guide and horizontal size guide as shown below. Exercise care to ensure the previously set adjustment chart is not misaligned.
  • Page 33 PRESS C1100/C1085 Repeat the scanning steps 12 to 14 four times for every adjustment chart. First time: Set the front side of the adjustment chart face up (turned away from the original glass), with its top edge positioned to the back side.
  • Page 34 Select whether to continue the scan measurement or to finish the scan measurement and calculate the adjustment value. To continue the scan measurement, press [No]. To finish the scan measurement and calculate the adjustment value, press [Yes]. Pressing [No] returns to the [Scan Adjustment Chart] screen on which the counter of [Chart Sheets] is added by one.
  • Page 35 PRESS C1100/C1085 Press [Close] to exit the adjustment. Scan Measurement Adjustment is then completed. To register adjustment values in a paper profile, press [Register]. 2-23...
  • Page 36: Registering The Paper Profile

    )Registering the paper profile Press [Register]. Press the number which you register a new paper profile. Enter the paper profile name and press [OK]. Enter the paper brand name in paper profile name. Check that the paper profile has been registered and press [Close].
  • Page 37 PRESS C1100/C1085 Press [Close] to exit the registration. Tips Use the registered paper profile when you carry out "Regular adjustment flow". 2-25...
  • Page 38: Back Side Fine Adjustment

    )Back side fine adjustment This adjustment is useful when the magnification of the back side image and the image position are adjusted according to the output result of the actual job data. Output about 3 sheets of the actual job data that you use from the tray that you conducted "Both Side Adjustment".
  • Page 39 PRESS C1100/C1085 Press [Back]. Check the back side magnification difference from the back side images back that are output as the second and third sheet among the output jobs in step 1. Pile the output jobs so that the front side of one sheet faces up, and the back side of another sheet faces up.
  • Page 40 Output about 3 sheets of the same job data that you output in step 1 from the same tray. Check the magnification difference of the back side of the paper that are output as the second and third sheet. Repeat from step 6 to step 8 until all magnification difference are cleared. Press [Paper Setting] on the [MACHINE] screen.
  • Page 41 PRESS C1100/C1085 Check the position difference of the back side among the back side images of the second and third output that were output after the magnification adjustment is completed. The black line in the figure shows the back side, and the blue dashed line shows the other side (front side).
  • Page 42: Image Quality Adjustment

    IMAGE QUALITY ADJUSTMENT Image quality adjustment for Image Controller IC-602 About Quality Adjustment To maintain stable color quality against a change in ambient temperature or humidity, a change of this machine conditions, or a change of the color tone due to the paper type or print mode, perform the image quality adjustment at periodic intervals.
  • Page 43: Adjustment Order

    PRESS C1100/C1085 Regular adjustment flow (High accuracy) )Adjustment timing For customers that require a high accuracy color reproduction, conduct the process when you activate the power every day. For other cases, conduct the process in the following cases. Before you output a job that the color is important...
  • Page 44: Adjustment Flow When Changing The Screen

    Adjustment flow when changing the screen )Adjustment timing When you change the setting of Custom Screen )Adjustment order Order Adjustment item Required time Reference Approximately Change setting of Custom Screen P.3-4 1 minute Approximately Gamma Automatic Adjustment P.3-6 1 minute P.3-7 (for i1Pro/i1Pro2/ES-...
  • Page 45: Contents Of The Image Quality Adjustment Items

    PRESS C1100/C1085 Contents of the image quality adjustment items This section describes the contents of the following 10 adjustment items. Change setting of Custom Screen (Page 3-4) Gamma Automatic Adjustment (Page 3-6) Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) (Page 3-7)
  • Page 46 Press [System Setting] on the [Administrator Setting Menu] screen, and then press [Expert Adjustment], [Quality Adjustment], and [Custom Screen] in sequence. Press the screen to be assigned to each screen type: [Screen 1], [Screen 2], and [Stochastic]. After setting, press [OK]. NOTICE [Dot190] is recommended as the configuration for [Screen...
  • Page 47: Gamma Automatic Adjustment

    PRESS C1100/C1085 )Gamma Automatic Adjustment On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen. Press [Execute Adjust Operation] on the [Adjustment Menu] screen. Press [Gamma Automatic Adj.] and press [OK]. Press [Exit [ADJUSTMENT]]. Wait for the display "Now adjusting" to disappear.
  • Page 48 )Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) NOTICE To measure the chart, use the X-rite Measure tool. Install the tool in advance. You can download the X-rite Measure tool at the following Web site. After installing the tool, restart the computer. ProfileMaker 5 v5.0.10: http://www.xrite.com/product_overview.aspx?ID=757&Action=Support On the touch panel of the main body, press [Adjustment] on the [MACHINE]...
  • Page 49 PRESS C1100/C1085 Select the desired chart type from "Measure Spectrophotometer-2", and press [Print Mode]. [Type2] is recommended. Press [Quality Adj.]. Press [Screen Pattern] and select the screen that is changed at "Change setting of Custom Screen" in the adjustment items (screen for Density balance adjustment) .
  • Page 50 Press Start on the control panel. The color chart is output for measurement using the spectrophotometer. Press [Exit PrintMode]. Press [Return], and return to the [Density Balance Adjustment Menu] screen. On the computer where the X-rite Measure tool. l has been installed, select [Start] - [All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].
  • Page 51 PRESS C1100/C1085 Connect the instrument to the computer. From the menu, click [Configuring]. In [Instrument], select [Eye-One Pro]. When [OK] is displayed, close the screen. From the menu, click [Measuring]. 3-10...
  • Page 52 From [Test Chart], select [Custom]. Specify [Columns] and [Rows], and click [OK]. When the chart type is "Type 1": [Columns] = 6, [Rows] = 5 When the chart type is "Type 2": [Columns] = 6, [Rows] = 13 Click [Start]. When the following message is displayed, horizontally place the spectrophotometer on the calibration dock and click [OK].
  • Page 53 PRESS C1100/C1085 Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it. When the following screen is displayed, place the spectrophotometer on the...
  • Page 54 From the [File] menu, select [Save As]. NOTICE If you use [Export Lab], an error occurs when registering the color adjustment data. When saving the data, always use [Save As]. Specify the destination to save. Specify USB memory or the computer connected to the machine via the network. Destination to save Description USB Memory...
  • Page 55 PRESS C1100/C1085 Click [Machine Manager Setting], and enter the administrator ID and password. Tips Contact your machine administrator for the administrator ID and the password. Click on [Color Measuring data Input]. Enter the file name for colorimetric data into [File Name], click [Browse] on the side of the file path, and select the colorimetric data saved in the computer.
  • Page 56 Select any one row in the list of 10 profiles, and press [Archived Data]. NOTICE No more than 10 pieces of data can be registered, however, the data can be overwritten. If desired, select the data to be overwritten. The colorimetric data can be synthesized and registered.
  • Page 57 PRESS C1100/C1085 )Density Balance Adjustment (for FD-5BT) NOTICE To measure the chart, use the Color Care measure. Install the Color Care measure in advance. To use Color Care measure, you need to acquire a license key. For details, refer to the user's guide that comes with Color Care measure.
  • Page 58 Select the [Type3] of "Measure Spectrophotometer-3", and press [Print Mode]. Press [Quality Adj.]. Press [Screen Pattern] and select the screen that is changed at "Change setting of Custom Screen" in the adjustment items (screen for Density balance adjustment) . Tips [Stochastic] is unavailable.
  • Page 59 Balance Adjustment Menu] screen. On the computer where the Color Care measure. l has been installed, select [Start] - [All Programs] - [Konica Minolta Color Care] - [Color Care measure]. Connect FD-5BT to the computer, and activate the power of FD-5BT.
  • Page 60 Click [Color Care - Job 0 - C1070 C1100 - density balance]. Then, click [FD5bt - Denbal Type 2sr - 13×6], and click [OK]. If the number of the color patch is 13 x 7, select [FD5bt - Denbal Type 2sr - 13x7]. When the following message appears, place the FD-5BT on the white calibration plate, and press the FD-5BT.
  • Page 61 PRESS C1100/C1085 Click [A], and measure charts from the right row (the row which has larger numbers). Hold down the side button of FD-5BT. When "bleep" sounds, slide FD-5BT while holding down the side button. Slide FD-5BT to the bottom side, then release the side button.
  • Page 62 Click [Density Balance...]. Enter the 14-digit identification number that is printed to the chart in [Print ID]. Example: 4025513011E66C Enter a filename in [Addendum]. Save the measurement data to the USB memory or the machine. Destination to save Description USB Memory Connect the USB memory to the computer, and click [Storage location] and [Select...].
  • Page 63 PRESS C1100/C1085 Click [Printer], and click [+]. Tips If you have added the machine as the destination to save, select the machine from [Printer]. Enter the information of the machine, and click [Add]. [Name]: Any name [Password]: Administrator password...
  • Page 64 Select any one row in the list of 10 profiles, and press [Archived Data]. NOTICE No more than 10 pieces of data can be registered, however, the data can be overwritten. If desired, select the data to be overwritten. The colorimetric data can be synthesized and registered.
  • Page 65 PRESS C1100/C1085 )Added procedures of Density Balance Adjustment (Registration of color measurement data using a USB memory) Press [Density Balance Data Reg/Del] on the [Density Balance Adjustment Menu] screen to display the [Density Balance Adj. Select any one row in the list of 10 profiles, and press [USB Memory].
  • Page 66 Tips With a row of the existing data selected in step 2, a confirmation dialog is displayed. To synthesize the selected data with the new data, press [Combination]. If conditions for screen type, paper type, or weight do not correspond to each other, [Combination] dims.
  • Page 67: Maximum Density Auto Adjustment (Ru)

    PRESS C1100/C1085 )Maximum Density Auto Adjustment (RU) NOTICE To enable this function, your service representative must specify the target maximum density value (target density) in advance. For more information, contact your service representative. Before you carry out Maximum Density Auto Adjustment (RU), check that the configuration of Screen 1 is Dot190. If Screen 1 is not configured to Dot190, perform "Change setting of Custom Screen"...
  • Page 68 Select the tray containing paper, then press [OK]. The paper profile of the tray is automatically switched to the paper profile that has been used to register the target density. Press Start on the control panel. A chart is printed out, and auto adjustment starts. Adjustment processing cannot be stopped until all charts are printed out.
  • Page 69: Check Setting Of Color Density Control

    PRESS C1100/C1085 )Check setting of Color Density Control Press [Adjustment] on the [MACHINE] screen. Press [Color Density Control]. Press [Basic Setting]. Check that the [Use Color Density Control] and [Periodical Adj. Execution] are configured to [ON]. Tips [Adjustment Execution Timing] is a configuration for a job that contains different screens and paper types.
  • Page 70 Press [Next]. Check that the [Switch Color(1st or 2nd)] is configured to [Precise]. NOTICE Select [Precise] or [Normal] depending on the situation. When you select [Precise], both the 1st color (YMCK) and the 2nd color (RGB) are corrected. When you want to prior the quality, select [Precise]. When you select [Normal], only the 1st color (YMCK) is corrected.
  • Page 71 PRESS C1100/C1085 Press [Exit [ADJUSTMENT]]. Automatic Adjustment is set. A chart is printed out periodically, and calibration is carried out automatically. 3-30...
  • Page 72: Color Density Manual Control

    )Color Density Manual Control Press [Adjustment] on the [MACHINE] screen. Press [Color Density Control]. Press [Color Density Manual Control]. This function is available only when [Use Color Density Control] is set to [ON] in [Color Density Control] - [Basic Setting]. Press [Print Mode].
  • Page 73 PRESS C1100/C1085 Press [Quality Adj.]. Press of [Screen Pattern] to select a screen. Press [Close]. Press Start. A chart is printed out, and calibration is carried out. 3-32...
  • Page 74: Exact Color (For I1Pro/I1Pro2/Es-1000/Es-2000, Or Fd-5Bt)

    [Administrator Setting] - [Network Setting] - [NIC Setting] The JSP setting is a setting that relates to a connection with a Java application server. Open the Start menu, and then click [All Programs] - [KONICA MINOLTA] - [Color Centro] - [KONICA MINOLTA Color Centro].
  • Page 75 PRESS C1100/C1085 Click [Settings] in [1. Paper Type / Screen Settings]. Set the [Paper Type] and [Screen Settings] on the [Paper Type/Screen Settings] screen and click [OK]. Example: Set the [Paper Type] to [Coated GL], and the [Screen Setting] to [Screen 1] (default).
  • Page 76 Click [Print]. Print the color chart that is to be measured using the instrument. On the [Print Chart] screen, set the [Copies] and [Paper Tray]. After setting, click [Print]. Click [Start]. 3-35...
  • Page 77 PRESS C1100/C1085 When the following message is displayed, place the instrument flat on the calibration dock and click [OK]. For FD-5BT, click [OK] while you press down the FD-5BT. Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it.
  • Page 78 Likewise, measure rows B to Q. The measured parts are color-displayed on the screen in the same way as for the chart. After you finish the chart measurement, click [Next]. After the message, [Calculating] is displayed, the [Operation steps] screen is displayed. Click [Next] and perform the rest of the measurement by following the instructions on the screen.
  • Page 79 PRESS C1100/C1085 Change the measurement number on the right side of [Select] and check the [ E Ave], [ E Max] values, and the [ a] [ b] graph of the Gray displayed within the [Gray Step] frame. As for the Gray, check the information...
  • Page 80: G7 Calibration (For I1Pro/I1Pro2/Es-1000/Es-2000, Or Fd-5Bt)

    In Color Centro, Exact Color is configured as default. You can use only either Exact Color or G7 calibration. To switch to G7 calibration, contact your service representative. Open the Start menu, and then click [All Programs] - [KONICA MINOLTA] - [Color Centro] - [KONICA MINOLTA Color Centro].
  • Page 81 PRESS C1100/C1085 Click [Settings] in [1. Paper Type / Screen Settings]. Set the [Paper Type] and [Screen Settings] on the [Paper Type/Screen Settings] screen and click [OK]. Example: Set the [Paper Type] to [Coated GL], and the [Screen Setting] to [Screen 1] (default).
  • Page 82 On the [Print Chart] screen, set the [Copies] and [Paper Tray]. After setting, click [Print]. Click [Start]. When the following message is displayed, place the instrument flat on the calibration dock and click [OK]. For FD-5BT, click [OK] while you press down the FD-5BT. Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it.
  • Page 83 PRESS C1100/C1085 Carry out the measurement in sequence from the 1st row. Hold down the side button of i1Pro/i1Pro2 or FD-5BT. When "bleep" sounds, slide i1Pro/i1Pro2 or FD-5BT while holding down the side button. Slide the spectrophotometer to the opposite side, then release the side button.
  • Page 84 Click [OK] on the [Information] screen. The calibration table is registered in the image controller. On the [Calibration Manager] screen, click [Accuracy Measurement] under [3. G7 Calibration]. Click [Print]. Print the color chart that is to be measured using the instrument. Click [Start].
  • Page 85 PRESS C1100/C1085 Measure the chart using the instrument. After you finish the chart measurement, click [OK]. NOTICE When the values of Ch and E* are not G7 standard as the result of the accuracy check, the dialogue is displayed. You can choose to recalculate and register the calibration table to fit in the target range or register as is in the dialogue.
  • Page 86: About Quality Adjustment

    Image quality adjustment for Image Controller IC-308/IC-310 About Quality Adjustment To maintain stable color quality against a change in ambient temperature or humidity, a change of this machine conditions, or a change of the color tone due to the paper type or print mode, perform the image quality adjustment at periodic intervals.
  • Page 87: Change Setting Of Custom Screen

    PRESS C1100/C1085 Adjustment flow when changing the screen )Adjustment timing When you change the setting of Custom Screen )Adjustment order Order Adjustment item Required time Reference Change setting of Custom Screen Approximately P.3-47 1 minute Gamma Automatic Adjustment Approximately P.3-49...
  • Page 88 Contents of the image quality adjustment items This section describes the contents of the following 9 adjustment items. Change setting of Custom Screen (Page 3-47) Gamma Automatic Adjustment (Page 3-49) Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) (Page 3-50) Added procedures of Density Balance Adjustment (Registration of color measurement data using a USB memory) (Page 3-59)
  • Page 89 PRESS C1100/C1085 Press [System Setting] on the [Administrator Setting Menu] screen, and then press [Expert Adjustment], [Quality Adjustment], and [Custom Screen] in sequence. Press the screen to be assigned to each screen type: [Screen 1], [Screen 2], and [Stochastic]. After setting, press [OK].
  • Page 90: Gamma Automatic Adjustment

    )Gamma Automatic Adjustment On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen. Press [Execute Adjust Operation] on the [Adjustment Menu] screen. Press [Gamma Automatic Adj.] and press [OK]. Press [Exit [ADJUSTMENT]]. Wait for the display "Now adjusting" to disappear. 3-49...
  • Page 91: Density Balance Adjustment (For I1Pro/I1Pro2/Es-1000/Es-2000)

    PRESS C1100/C1085 )Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) NOTICE To measure the chart, use the X-rite Measure tool. Install the tool in advance. You can download the X-rite Measure tool at the following Web site. After installing the tool, restart the computer.
  • Page 92 Select the desired chart type from "Measure Spectrophotometer-2", and press [Print Mode]. [Type2] is recommended. Press [Quality Adj.]. Press [Screen Pattern] and select the screen that is changed at "Change setting of Custom Screen" in the adjustment items (screen for Density balance adjustment) .
  • Page 93 PRESS C1100/C1085 Press Start on the control panel. The color chart is output for measurement using the spectrophotometer. Press [Exit PrintMode]. Press [Return], and return to the [Density Balance Adjustment Menu] screen. On the computer where the X-rite Measure tooL. l has been installed, select [Start] - [All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].
  • Page 94 Connect the instrument to the computer. From the menu, click [Configuring]. In [Instrument], select [Eye-One Pro]. When [OK] is displayed, close the screen. From the menu, click [Measuring]. 3-53...
  • Page 95 PRESS C1100/C1085 From [Test Chart], select [Custom]. Specify [Columns] and [Rows], and click [OK]. When the chart type is "Type 1": [Columns] = 6, [Rows] = 5 When the chart type is "Type 2": [Columns] = 6, [Rows] = 13 Click [Start].
  • Page 96 Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it. When the following screen is displayed, place the spectrophotometer on the patch at the top in the upper left, and press the button for the spectrophotometer.
  • Page 97 PRESS C1100/C1085 From the [File] menu, select [Save As]. NOTICE If you use [Export Lab], an error occurs when registering the color adjustment data. When saving the data, always use [Save As]. Specify the destination to save. Specify USB memory or the computer connected to the machine via the network.
  • Page 98 Click [Machine Manager Setting], and enter the administrator ID and password. Tips Contact your machine administrator for the administrator ID and the password. Click on [Color Measuring data Input]. Enter the file name for colorimetric data into [File Name], click [Browse] on the side of the file path, and select the colorimetric data saved in the computer.
  • Page 99 PRESS C1100/C1085 Select any one row in the list of 10 profiles, and press [Archived Data]. NOTICE No more than 10 pieces of data can be registered, however, the data can be overwritten. If desired, select the data to be overwritten.
  • Page 100: Density Balance Adjustment (For Fd-5Bt)

    )Added procedures of Density Balance Adjustment (Registration of color measurement data using a USB memory) Press [Density Balance Data Reg/Del] on the [Density Balance Adjustment Menu] screen to display the [Density Balance Adj. Data Register / Del]. Select any one row in the list of 10 profiles, and press [USB Memory].
  • Page 101 PRESS C1100/C1085 Tips With a row of the existing data selected in step 2, a confirmation dialog is displayed. To synthesize the selected data with the new data, press [Combination]. If conditions for screen type, paper type, or weight do not correspond to each other, [Combination] dims.
  • Page 102: Maximum Density Auto Adjustment (Ru)

    )Maximum Density Auto Adjustment (RU) NOTICE To enable this function, your service representative must specify the target maximum density value (target density) in advance. For more information, contact your service representative. Before you carry out Maximum Density Auto Adjustment (RU), check that the configuration of Screen 1 is Dot190. If Screen 1 is not configured to Dot190, perform "Change setting of Custom Screen"...
  • Page 103 PRESS C1100/C1085 Select the tray containing paper, then press [OK]. Press Start on the control panel. A chart is printed out, and auto adjustment starts. When the adjustment is completed, you return to the [Max. Density Auto Adj. (RU)] screen.
  • Page 104: Check Setting Of Color Density Control

    )Check setting of Color Density Control Press [Adjustment] on the [MACHINE] screen. Press [Color Density Control]. Press [Basic Setting]. Check that the [Use Color Density Control] and [Periodical Adj. Execution] are configured to [ON]. Tips [Adjustment Execution Timing] is a configuration for a job that contains different screens and paper types.
  • Page 105 PRESS C1100/C1085 Press [Next]. Check that the [Switch Color(1st or 2nd)] is configured to [Precise]. NOTICE Select [Precise] or [Normal] depending on the situation. When you select [Precise], both the 1st color (YMCK) and the 2nd color (RGB) are corrected.
  • Page 106 Press [Exit [ADJUSTMENT]]. Automatic Adjustment is set. A chart is printed out periodically, and calibration is carried out automatically. 3-65...
  • Page 107: Color Density Manual Control

    PRESS C1100/C1085 )Color Density Manual Control Press [Adjustment] on the [MACHINE] screen. Press [Color Density Control]. Press [Color Density Manual Control]. This function is available only when [Use Color Density Control] is set to [ON] in [Color Density Control] - [Basic Setting].
  • Page 108 Press [Quality Adj.]. Press of [Screen Pattern] to select a screen. Press [Close]. Press Start. A chart is printed out, and calibration is carried out. 3-67...
  • Page 109: Controller Calibration (Ic-308/Ic-310)

    PRESS C1100/C1085 )Controller Calibration (IC-308/IC-310) Use a USB cable to connect EFI Spectrometer ES-1000/ES-2000 to your computer. For details about how to use EFI Spectrometer ES-1000/ES-2000, refer to the manual supplied with the spectrophotometer. Open the Start menu, and then click [All Programs] - [Fiery] - [Fiery Command WorkStation 5].
  • Page 110 Click [Job Center] - [Calibrate] in sequence. Calibrator starts. Select the printing preferences for calibration. Example: Configure the [Calibrate] to [Coated (128gm2)], the [Paper source] to [Tray 3], and the [Measurement method] to [EFI ES-2000]. Click [Continue]. A chart is printed out in a matter of time after this machine started running.
  • Page 111 PRESS C1100/C1085 Securely place EFI Spectrometer ES- 1000/2000 in the calibration cradle, then click [Continue]. Stack 10 sheets of blank paper whose type is the same as that of the paper where chart has been printed, and place the printed chart on top of it.
  • Page 112 Click [Apply & Close]. The calibrated measurement values are applied. 3-71...
  • Page 113 PRESS C1100/C1085 Blank Page 3-72...
  • Page 114 2016. 6 © 2016...