(5) Press the "TIMER
MODE" button to
send the code to
the indoor unit.
Function setting
(6) Press the "MODE"
button to access the
function setting mode.
(7) Press the " " or the " " buttons to select the function number.
Each time the "MODE" button is pressed, it switches between the one's
place and the ten's place.
(8) Press the "FAN" button to proceed to
setting the number. (Press the "FAN"
button again to return to the function
number selection.)
(9) Press the " " or the " " buttons to select the setting number.
Each time the "MODE" button is pressed, it switches between the one's
place and the ten's place.
(10)
Press the "START/
STOP" button once to
send the information. A
beeping sound will be
heard if the command
is accepted.
* In the following cases the setting signal is not read and a buzzer sounds.
The function setting No. is set out of range
: Pi Pi Pi Pi Pi
En-7
Correct code:
Pi Pi
Wrong code:
No Response
Pi Pi
Pi
PiPiPi
Case1 : When setting number is 1 digit.
(11-1) Indoor unit will display the function setting number on "OPERATION"
(GREEN), "TIMER
" (ORANGE) and "FILTER
Flashing times of
Flashing times of
function numbers
function numbers
(the ten's place)
(the one's place)
(Example) Function number : 30, Setting number : 01
0.5sec ON / 0.5sec OFF
OPERATION LAMP
(GREEN)
3 times
TIMER LAMP
(ORANGE)
0.5sec ON / 0.5sec OFF
FILTER LAMP
1 time
(RED)
(Phase1) : 12sec
* Number 0 setting will not indicate TIMER LAMP and FILTER LAMP.
Case2 : When setting number is 2 digits.
(11-2) Indoor unit will display the function setting number on "OPERATION"
(GREEN), "TIMER
" (ORANGE) and "FILTER
Phase1
Flashing times of
Flashing times of
function numbers
function numbers
(the ten's place)
(the one's place)
Phase2
OFF
(Example) Function number : 26, Setting number : 31
0.5sec ON / 0.5sec OFF
OPERATION LAMP
2 times
(GREEN)
0.5sec ON / 0.5sec OFF
TIMER LAMP
(ORANGE)
0.5sec ON / 0.5sec OFF 0.5sec ON / 0.5sec OFF
FILTER LAMP
1 time
(RED)
(Phase1) : 12sec
* Number 0 setting will not indicate TIMER LAMP and FILTER LAMP.
" (RED) light.
Flashing times of
setting numbers
(the one's place)
3 times
OFF
1 time
(Phase1) : 12sec
" (RED) light.
Flashing times of
setting numbers
(the one's place)
The display of "Phase1" and "Phase2" is
alternately repeated.
OFF
Flashing times of
setting numbers
(the ten's place)
OFF
6 times
OFF
3 times
(Phase2) : 12sec
...
...
...
...
...