This gas appliance should be installed and serviced by a qualifi ed installer to conform with local codes.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your
area, for example: in Massachusetts State:
The appliance off valve must be a "T" handle gas cock.
The fl exible connector must not be longer than 36".
The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a direct
vent sealed combustion product.
A carbon monoxide detector is required in all rooms containing gas fi red appliances.
WARNING: This product must be installed by a licensed plumber or gas fi tter when installed within the
commonwealth of Massachusetts.
Un-vented room appliance shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00
through 7.00.
Sellers of un-vented propane or natural gas-fi red space / room appliances shall provide to each purchaser
a copy of 527 CMR 30.00 upon the sale of the appliance from http://www.napoleonfi replaces.com/
Webshare/installation_manuals/mass_requirements.pdf
In absence of local codes, install the appliance to the current National Fuel Gas Code, ANSI Z223.1
Installation Code which can be obtained from:
American National Standards Institute Inc.
New York, NY 10018
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be
isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). When
installed with a blower the junction box must be electrically connected and grounded in accordance with local
codes. In the absense of local codes, use the current ANSI / NFPA 70 National Electric Code. In the case
where the blower is equipped with a power cord it must be connected into a properly grounded receptacle.
The grounding prong must not be removed from the cord plug.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location for a
Napoleon® appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The
location of windows, doors and the traffi c fl ow in the room
where the appliance is to be located should be considered.
If possible, you should choose a location where the vent will
pass through the house without cutting a fl oor or roof joist.
When the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
1.4

GENERAL INFORMATION

For your satisfaction, this heater has been test-fi red to assure its operation and quality!
Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane.
Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold
pressure under fl ow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.
No external electricity (110 volts or 24 volts) is required for the gas system operation. Expansion / contraction noises dur-
ing heating up and cooling down cycles are normal and are to be expected.
The heater is equipped with a pilot light safety system referred to as an oxygen depletion sensor and is designed to turn
off the heater if not enough fresh air is available.
Maximum input is 30,000 BTU/h for natural gas and propane. When the heater is installed at elevations above 2,000 ft
and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input
rating shall be reduced at the rate of 4% for each additional 1,000 ft.
W415-0796 / 05.15.09
1430 Broadway
or
National Fire Protection Association Inc.
Batterymarch Park
Quincy, MA 02269
www.nficertified.org
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Appliance
Institute ® (NFI) as NFI Gas
Specialists