Advertisement

Quick Links

CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTiFiEd UNdER AmERiCAN NATiONAL STANdARdS, ANSi Z21.11.2, vOLUmE ii FOR UNvENTEd ROOm HEATERS.
GVF36P
PROPANE
GVF36N
NATURAL GAS
UNvENTEd miLLivOLT
SySTEm
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
- This is an unvented gas-fired heater that uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation
air must be provided.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfireplaces.com • ask@napoleon.on.ca
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
103 Miller Drive, Crittenden, Kentucky, USA, 41030
APPLY SERIAL NUMBER LABEL FROM CARTON
Serial No.
MODEL NO.
W415-0297 / L / 10.23.08
1
W415-0297 / L / 10.23.08

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GVF36P

  • Page 1: Safety Information

    Provisions for adequate combustion and ventilation Serial No. air must be provided. MODEL NO. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfireplaces.com • ask@napoleon.on.ca $10.00 W415-0297 / L / 10.23.08...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTrOduCTION WARRANTy dimENSiONS GENERAL iNSTRUCTiONS GENERAL iNFORmATiON CARE OF PLATEd PARTS INsTallaTION COmbUSTiON ANd vENTiLATiON AiR PROviSiONS dETERmiNiNG CONFiNEd OR UNCONFiNEd SPACE GAS iNSTALLATiON ELECTRiCAL CONNECTiON FraMING FINIshING NAiLiNG TAb iNSTALLATiON miNimUm mANTEL ANd ENCLOSURE CLEARANCES GRATE ANd LOG PLACEmENT CHARCOAL EmbERS GLOWiNG EmbERS HOOd...
  • Page 3: Introduction

    1.0 INTrOduCTION WARNING • ANY CHANGES TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this heater be modified. • Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the heater.
  • Page 4: Warranty

    NAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON® reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
  • Page 5: Dimensions

    dImENSIONS FIGurE 1.2b FIGurE 1.2a FIGurE 1.2c GENErAL INSTruCTIONS This gas heater should be installed and serviced by a qualified installer to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, for example: in Massachusetts State: •...
  • Page 6: General Information

    GENErAL INFOrmATION WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people---pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol, those at high altitudes--- are more affected by carbon monoxide than others.
  • Page 7: Installation

    2.0 INSTALLATION Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2” away from the side of the fireplace. Thereafter, the depth of any protrusions must be of equal to or less than the distance from the side of the fireplace up to a depth of 6”, after which no greater clearance than 6”...
  • Page 8: Combustion And Ventilation Air Provisions

    COmBuSTION ANd vENTILATION AIr prOvISIONS This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space.
  • Page 9 Without sufficient fresh air for proper operation, poor fuel combustion can result. Carbon Monoxide is a result of poor combustion. If additional fresh air is required, use one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or the applicable local code.
  • Page 10: Gas Installation

    GAS INSTALLATION WARNING Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts). NOTE: All gas connections must be contained within the heater when complete. 1. Move the heater into position and secure to the floor. 2.
  • Page 11: Framing

    3.0 FrAmING It is best to frame your fireplace after it is positioned. Use 2x4’s and frame to local building codes. FIGurE 3.0 ” 3” ” ” ” W415-0297 / L / 10.23.08...
  • Page 12: Finishing

    4.0 FINIShING NAILING TAB INSTALLATION FIGurE 4.1 To install the fireplace face flush with the finished wall, position the framework to accommodate the thickness of the finished wall. Bend out the four nailing tabs, attached on either side of the fireplace and secure to the 2x4 framing. The tabs will facilitate the installation of either a ”...
  • Page 13: Grate And Log Placement

    NOTE: PhazEr logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and re- alistic glowing effect that is different in every installation. Take the time to carefully position the glow- ing embers for a maximum glowing effect.
  • Page 14: Hood

    hOOd WARNING Fireplace screens must be closed while the appliance is in operation. FIGurE 4.6b FIGurE 4.6a WARNING Hood Curtain mesh The heater must not be used when the hood is removed. Hook the hood over the lip of the curtain support plate. LOGO pLACEmENT FIGurE 4.7 Remove the backing of the logo supplied and place on the screen cover, as...
  • Page 15: Optional Blower Installation

    5.0 OpTIONAL BLOwEr INSTALLATION INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be BLOWER electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current ANSI/NFPA 70 National Electrical Code. If the fireplace was not previously equipped with a blower: Route a grounded 2-wire, 60hz power cable to the junction box.
  • Page 16: Operation

    6.0 OpErATION If heater shuts off, do not relight until you provide fresh air. If heater keeps shutting off, have it serviced. Keep burner and control compartment clean. When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the “burn-in”...
  • Page 17: Oxygen Depletion Sensor Pilot Cleaning

    OxyGEN dEpLETION SENSOr pILOT CLEANING This procedure must be performed by a qualified service person! Inspect the pilot for any visible contamination or debris FIGurE 7.1b FIGurE 7.1a (usually lint, pet hair, spider webs, carpet fibre, etc.) CORRECT PILOT INCORRECT and remove.
  • Page 18: Replacements

    OxyGEN dEPLETiON SENSOR SySTEm - NG W662-0005 OxyGEN dEPLETiON SENSOR SySTEm - LP W680-0004 THERmOPiLE W725-0030 NATURAL GAS vALvE W725-0031 PROPANE GAS vALvE W385-0334 NAPOLEON LOGO W750-0112 20FT OF WiRE GL-664 oNe pIeCe LoG SeT (W135-0335) W361-0016 GLOWiNG EmbERS W550-0001 CHARCOAL EmbERS W010-0764...
  • Page 19 ACCESSOrIES ParT NO. dEsCrIPTION HOikG-3 HERiTAGE ORNAmENTAL iNSETS - bLACk GOLd PLATEd HOibC-3 HERiTAGE ORNAmENTAL iNSETS - bRUSHEd COPPER PLATEd HOibG-3 HERiTAGE ORNAmENTAL iNSETS - bRUSHEd GOLd PLATEd HOiSS-3 HERiTAGE ORNAmENTAL iNSETS - bRUSHEd STAiNLESS STEEL dOiG-2 diAmONd ORNAmENTAL iNSETS - GOLd PLATEd dOikG-2 diAmONd ORNAmENTAL iNSETS- bLACk GOLd PLATEd dOibC-2...
  • Page 20: Trouble Shooting Guide

    10.0 TrOuBLE ShOOTING GuIdE SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; Pilot flame is not large enough or - Turn up the pilot flame. pilot stays on. not engulfing the thermopile. - Replace pilot assembly. Thermopile shorting. - Clean thermopile connection tot he valve. Reconnect. - Replace thermopile / valve.
  • Page 21 SYMPTOM PROBLEM TEST SOLUTION Pilot goes out while Gas piping is undersized. - Turn on all gas appliances and see if pilot flame flutters, standing; Main burner diminishes or extinguishes, especially when main burner is in ‘OFF’ position. ignites. Monitor appliance supply working pressure. - Check if supply piping size is to code.
  • Page 22: Service History

    11.0 SErvICE hISTOry TP - SERviCE HiSTORy W415-0297 / L / 10.23.08...
  • Page 23: Notes

    12.0 NOTES NOTES TP - NOTES W415-0297 / L / 10.23.08...
  • Page 24 NOTES TP - NOTES W415-0297 / L / 10.23.08...

This manual is also suitable for:

Gvf36n

Table of Contents