Page 1
Black R2020 Model Pantone 534 Blue - 100/80/30/5 IR Video Thermometer Pantone 485 Red - 10/100/100/5 Pantone 123 Yellow - 0/27/100/ & Data Logger Instruction Manual reedinstruments 1-877-849-2127 | info@reedinstruments.com www.reedinstruments.com...
Blue - 100/80/30/5 Pantone 534 Blue Yellow - 0/27/100/0 Pantone 123 Yellow For service on this or any other REED product or information on other Red - 10/100/100/5 Pantone 485 Red Yellow - 0/27/100/0 REED products, contact REED Instruments at info@reedinstruments.com...
Features • Measures air temperature, RH % dewpoint, and wet bulb • High temperature range up to 2200°C (3992°F) • Captures images (JPEG) and videos (3GP) • 2.2” TFT LCD display • 640 x 480 pixels (30 million pixels) • 72MB internal memory •...
Page 4
Dimensions: 205 x 62 x 155mm (8.07 x 2.4 6.1”) Weight: 410g (14.46oz) Includes: One mini-tripod, type-k thermocouple probe, AC adapter, USB adapter, and hard carrying case IR Temperature Temp. range: -50 to 2200°C (-58 to 3992°F) Accuracy: 20 to 500°C (68 to 932°F): ±1%±1.0°C (1.8°F); 500 to 1000°C (932 to 1832°F): ±1.5%;...
Air temp. accuracy: ±0.5°C (0.9°F): 10 to 40°C; ±1.0°C (1.8°F): >40°C Dewpoint and Wet Bulb temp. accuracy: ±0.5°C (0.9°F): 10 to 40°C; ±1.0°C (1.8°F): >40°C Relative humidity accuracy: ±3% RH: 40% to 60%; ±3.5% RH: 0% to 40% and 60% to 80%; ±5% RH: 0% to 20% and 80% to 100% Instrument Description 1.
Operating Instructions To turn the meter on or off, press and hold the Power button. The meter will beep indicating that it has been turned on or off. Main Menu When you turn the meter on you will enter the main menu screen. There are six functions in the main menu to choose from.
Dewpoint Measurement In the main menu, highlight and select the DEWPOINT function. The Dewpoint function measures IR temperature, air temperature, relative humidity, dewpoint temperature, and wet bulb temperature. The bottom gradient bar displays the current temperature/dewpoint ratio percentage. Press and hold the trigger to take a measurement. Datalogging In the main menu, highlight and select DATALOG.
Browsing Videos Press the Up and Down buttons to scroll through the video thumbnails, and press the Enter button to play the video. To exit video playback press the ESC button. To delete a video press the Enter button during playback and press Up to delete or Down to cancel.
USB cable into the AC adapter or by plugging the USB cable directly into a computer. If you are experiencing any issues with the meter or any other REED Instrument please contact REED Instruments at info@reedinstruments.com. Notes _________________________________________...
Need help?
Do you have a question about the R2020 and is the answer not in the manual?