Mpa Multi-Zone Specifications Outdoor Units (1.5 - 2.5 Ton) - Lennox MPA009S4S Service Manual

Mini-split systems
Table of Contents

Advertisement

1.7.
MPA Multi-Zone Specifications Outdoor Units (1.5 - 2.5 Ton)
Nominal Size - Tons
Outdoor Unit Model No.
Number of Zones
AHRI Ratings
1
High Temperature Heating - Btuh
Low Temperature Heating - Btuh
Energy Star
Ambient Temperature Range - °F
Sound Data (dBA)
Refrigerant
Maximum line length with furnished charge (per zone) - ft.
Additional charge required per ft. - oz.
Compressor
Connections - in.
Maximum length for all rooms - ft.
Maximum length for one indoor unit - ft.
Maximum height
difference between
indoor unit and outdoor
unit
Maximum difference in level between indoor units - ft.
Outdoor
Fan
Outdoor Coil
Design Pressure
Shipping Data
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase
Maximum Overcurrent Protection (amps)
2
Outdoor Fan Motor
NOTE - Per AHRI, the certified ratings for systems are valid for all combinations of indoor units with the specific outdoor units listed above and in the AHRI Directory of
Certified Equipment. Please visit http://www.ahridirectory.org for further details and latest updates.
Ratings are AHRI certified to AHRI Standard 210/240-2008;
1
• Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F dry bulb/75°F wet bulb outdoor air temperature.
• High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
• Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
3
NOTE - Adaptors are furnished for the gas pipe connections:
018 - (2) 3/8 x 1/2 in.
030 - (3) 3/8 x 1/2 in.
System Type
Cooling - Btuh
SEER
EER
HSPF (Region IV)
AHRI Reference Number
Cooling
Heating
Cooling
Heating
Charge furnished (R-410A)
No. and Type
Refrigerant oil type
Refrigerant oil charge - oz.
Liquid+Gas pipe (flare)
Outdoor unit ABOVE
indoor unit - ft.
Outdoor unit BELOW
indoor unit - ft.
(No.) Diameter - in.
Total air volume - cfm
rpm
Number of rows
Fins per inch
Fin type
Tube outside diameter - in.
Tube type
Net face area - ft.
2
PSIG
Net/Shipping weight (lbs.)
Minimum circuit ampacity
3
Compressor Rated load amps
Rated load amps
Output - W
1.5
MPA018S4M
2
Ducted
Non-Ducted
17,000
18,000
18,000
18,500
10,900
11,000
18.00
21.00
12.50
12.50
8.5
9.6
8129621
8129607
Yes
Yes
5 - 122
–13 - 76
57
62
4 lbs. 4 oz.
25
0.161
Twin-Rotary
ESTER OIL VG74
16.9
(2) 1/4 + (2) 3/8
98
66
33
49
33
(1) - 18
1470
750
2
14
Hydrophilic aluminium
3/8
Rifled copper tubing
4.9
550/340
106 / 115
208/230V
20
18
10
0.74
50
11
2.5
MPA030S4M
Up to 3
Ducted
Non-Ducted
27,000
25,000
32,000
32,000
20,000
20,000
16.50
22.00
9.50
12.50
8.8
9.6
8129624
8129613
No
Yes
5 - 122
–13 - 76
59
62
6 lbs. 3 oz.
25
0.161
Twin-Rotary
ESTER OIL VG74
27.7
(3) 1/4 + (3) 3/8
148
82
33
49
33
(1) - 22
2060
850
1.6
15
3/8
6.42
550/340
144 / 155
208/230V
25
20
12
0.90
120