Lennox MPA009S4S Service Manual page 96

Mini-split systems
Table of Contents

Advertisement

Running Light
State of
Short Flashes
Timer Light
1 time
OFF
2 times
OFF
4 times
OFF
5 times
OFF
6 times
OFF
7 times
OFF
8 times
OFF
1 time
ON
2 times
ON
3 times
ON
4 times
ON
5 times
ON
6 times
ON
1 time
Flash
2 times
Flash
4 times
Flash
5 times
Flash
6 times
Flash
7 times
Flash
Running Light
State of
Short Flashes
Timer Light
1 time
OFF
2 times
OFF
4 times
OFF
5 times
OFF
6 times
OFF
7 times
OFF
8 times
OFF
1 time
ON
2 times
ON
3 times
ON
4 times
ON
5 times
ON
6 times
ON
1 time
Flash
2 times
Flash
4 times
Flash
5 times
Flash
7 times
Flash
8 times
Flash
Table 9.
Indoor Unit Fault Codes (09/24)
Display
Description
E0
Indoor unit EEPROM error
E1
Communication error between indoor and outdoor units
E3
Indoor fan speed error
E4
Indoor return air temperature sensor error
E5
Indoor coil temperature sensor error
EC
Low refrigerant
EE
High water level alarm
F0
Outdoor current overload sensed
F1
Outdoor ambient temperature sensor error
F2
Outdoor coil temperature sensor error
F3
Compressor discharge temperature sensor error
F4
Outdoor unit EEPROM error
F5
Outdoor unit fan speed error
P0
Inverter module IPM error
P1
High or low voltage protection
P3
Outdoor unit low temperature lockout
P4
Compressor drive error
--
Mode conflict
P6
Compressor high- or low-pressure switch open.
Table 10. Indoor Unit Fault Codes (09/30-48)
Display
Description
E0
Indoor unit EEPROM error
E1
Communication error between indoor and outdoor units
E3
Indoor fan speed error
E4
Indoor return air temperature sensor error
E5
Indoor coil temperature sensor error
EC
Low refrigerant
EE
High water level alarm
F0
Outdoor current overload sensed
F1
Outdoor ambient temperature sensor error
F2
Outdoor coil temperature sensor error
F3
Compressor discharge temperature sensor error
F4
Outdoor unit EEPROM error
F5
Outdoor unit fan speed error
P0
Inverter module IPM error
P1
High or low voltage protection
P3
Outdoor unit low temperature lockout
P4
Compressor drive error
P6
Compressor high- or low-pressure switch open.
P7
Outdoor IGBT temperature sensor error
96