9.7.

MPC Multi-Zone Specifications (1.5 - 2.5 Ton)

Nominal Size - Tons
Outdoor Unit Model No.
Number of Zones
Ambient Temperature Range
- °F
Sound Data (dBA)
Refrigerant
Charge furnished (R-410A)
Maximum line length with furnished charge (per
Additional charge required per ft. - oz.
Compressor
Refrigerant oil type
Refrigerant oil charge - oz.
Connections
Liquid+Gas pipe (in.) flare
Max. length for all rooms - ft.
Max. length for one indoor unit - ft.
Max. height difference between indoor and outdoor
Max. height difference between indoor units - ft.
(No.) Diameter - in.
Outdoor
Total air volume - cfm
Fan
Outdoor Coil
Tube outside diameter - in.
Application area - sq. ft.
Design Pressure
Shipping Data
Net/Shipping weight (lbs.)
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase
Maximum Over-current Protection (amps)
2
Minimum circuit ampacity
3
Outdoor Fan
Motor
NOTE - Per AHRI, the certified ratings for systems are valid for all combinations of indoor units with the specific outdoor units listed above and in the AHRI Directory of
Certified Equipment. Please visit
Ratings are AHRI certified to AHRI Standard 1230-2010 with Addendum 2;
1
• Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F dry bulb/75°F wet bulb outdoor air temperature.
• High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
• Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
3
NOTE - Adaptors are furnished for the gas pipe connections:
018 - (2) 3/8 x 1/2 in.
030 - (3) 3/8 x 1/2 in.
MPC018S4M
Cooling
Heating
Cooling
Heating
zone) - ft.
No. and Type
(2) 1/4 + (2) 3/8
units - ft.
Motor rpm
Number of rows
Fins per inch
Fin type
Tube type
Net face area - ft.
2
PSIG
Output - W
http://www.ahridirectory.org
for further details and latest updates.
1.5
2
–13 - 122
–13 - 86
58.5
58.5
4 lbs. 1 oz.
25
0.16
(1) Rotary
VG74
15.20
131
82
49
33
(1) 21
1765
750/500
2
18
Hydrophilic Aluminum
3/8
Rifled Copper Tubing
5.90
235 - 345
540 / 340
100 / 109
208/230V
25
18
80
48
2
MPC024S4M
Up to 3
–13 - 122
–13 - 86
61
61
5 lbs. 11 oz.
25
0.16
(1) Rotary
VG74
21.00
(3) 1/4 + (3) 3/8
197
98
49
33
(1) 22
2130
1050/900/850
2
18
3/8
8.18
355 - 515
540 / 340
140 / 151
208/230V
30
24.5
120
2.5
MPC030S4M
Up to 3
–13 - 122
–13 - 86
61
61
5 lbs. 11 oz.
25
0.16
(1) Rotary
VG74
21.00
(3) 1/4 + (3) 3/8
197
98
49
33
(1) 22
2130
1050/900/850
2
18
3/8
8.18
355 - 515
540 / 340
140 / 151
208/230V
30
24.5
120